Muhammad Naeem Khan, Insrument Technician

Muhammad Naeem Khan

Insrument Technician

Oil and gas company Ltd

Lieu
Pakistan - Hyderabad
Éducation
Diplôme, Trade Technology, Electro Technique, Electric matarial,Maths..
Expérience
35 years, 7 Mois

Partager Mon CV

Empêcher usager


Expériences professionnelles

Total des années d'expérience :35 years, 7 Mois

Insrument Technician à Oil and gas company Ltd
  • Pakistan - Islamabad
  • Je travaille ici depuis septembre 1995

TECHNICAL SKILL
• Having full command in trouble shooting of pneumatic and electronic instruments DCS / PLC system.
• Having full command on calibration configurations loop checking testing of pressure, level, flow and temperature instrumentation.
• Having full command to read and understand schematic drawing, P&IDS, PFDS, Logic drawings and Maintenance Management system.

OIL & GAS DEVELOPMENT COMPANY LIMITED
Working as Instrument Technician BPS-13SINCE 1995.
Qadir Pur Gas Field (25th sep1995 to oct1999)worked as instrument Tech: at Qadir pur Gas Field during this tenure I worked on suvimac II Turbine control DCS system, Carlo gavazi relay logic ESD System, Local control penal of Roselace relay logic for Suprex membrane Train.
KUNNAR LPG PLANT AND CONDENSATE FIELD
Presently working at kunnar LPG Plant & condensate Field from October 1999 during this period I am working on Murphymatic selectronic controller 500 series Engine Ignition control, Microgaurd selectronic control for compressor and Engine control.

Insrument Technician à Zalin Pvt Ltd
  • Pakistan - Karachi
  • avril 1995 à août 1995

HUBCO POWER PROJECT (April1995 to August 1995)


Worked with Zelin Pvt Limited as Instrument Technician during this period I worked on installation calibration and loop checking of Demin: plant Desl: plant auxiliary boiler and main boiler unit.

Insrument Technician à Wescon international BV
  • Émirats Arabes Unis - Abu Dhabi
  • septembre 1992 à août 1994

WESCON INTERNATIONAL BV UAE (Sep 1992 to August 1994)
• Worked with Wescon Int:B.V. Abu Dhabi UAE at Instrument Technician during this tenure I worked on flowing projects
• Ummul Nar Refinery Expansion II project sep 1992 to Jan 1993 during this period I worked on TDC-3000 DCS System.
• GASCO BUHASA SHATDAWN (Feb 1993 to March 1993) work involve calibration of instruments and control valves.
• ADCO WATER INJECTION & POER PROJECT (May 1993toto Dec 1993) Worked on upgrading of 28 no: clusters, the work involves calibration installation loop checking of instruments Toshiba PLC logic RTU system for monitoring of injection wells parameter

Insrument Technician à procon Pvt Ltd
  • Pakistan - Karachi
  • mars 1988 à août 1992

TECHNICAL SKILL
• Having full command in trouble shooting of pneumatic and electronic instruments DCS / PLC system.
• Having full command on calibration configurations loop checking testing of pressure, level, flow and temperature instrumentation.
• Having full command to read and understand schematic drawing, P&IDS, PFDS, Logic drawings and Maintenance Management system.
PROCON PVT LIMITED (March 1988 to sep 1992)
Worked as instrument Tech: at project of Union Texas oil and gas field work involve calibration, installation loop checking and commissioning of separators and wellheads.

Éducation

Diplôme, Trade Technology, Electro Technique, Electric matarial,Maths..
  • à Metallurgical Training Center Pakistan Steel
  • août 1987

N/A

Specialties & Skills

Installation
Pressure
Testing
Expert in process and control instrumentation

Langues

Anglais
Moyen
Urdu
Expert
Hindi
Moyen