Instrumentation Technician
Khaleej Sugar Refinery, AlGhurair Group
Total years of experience :7 years, 9 Months
Industry: Sugar Refinery Reporting to: Supervisor & Eng. Instrumentation Technician Feb21 to Date
• Overhauling the refinery in the lines of E&I Manager. Instruments Dismantling & Installation, after overhauling.
• Performing Preventive Maintenance, periodic maintenance, break down maintenance, predictive maintenance in support of DCS system.
• Troubleshooting of Instruments and control system for production line, Process, divisions lines,
• Troubleshooting of Pressure, Temperature, Level and Flow Loops, Pressure Transmitters, Level Transmitters, RTD'S, Thermocouples, etc.
• Calibrations of Valves, Transmitters, Gauges, Sensors, Meters & Switches
• Ad-hoc Work, Follow SOPs for all operations, Wear appropriate personal protective eqp.
Transmitters Testing & Calibration (PT, FT-Rosemount)
Level and Pressure Switches testing collaboration with DCS
Project:
Qatar Petroleum, Dolphin Energy & RAS Gas
Responsibilties:
Overhauling, Maintenance of all kinds of control valves, On/Off Valves.
Maintenance and Testing of Flame Scanners and ignition rods.
Pressure transmitter calibration (wikai)
FT transmitter calibration (Honeywell std 924)
PT 100, thermocouple testing and new installation
Flow tube testing and new installation
Relay testing and sov testing 24vdc
Power supply testing 24vdc, 3.5A, 5A, 10A,
Butterfly valve maintenance
Primary cable and secondary cable dressing
Metallic conduit pvc conduit put in instrument cable
Project: ADGAS
Location: DAS ISLAND, ABu Dhabi
Responsibilities:
Calibration of Control Valves used in Oil & gas I >P (PK 200)
Temperature Calibration of Thermo couple K
Type Fluke 707 Model
Hot Loop and cold loop checking Fluke
SOV, pressure switches and temperature
switches maintenance
Control valve checking and maintenance with positioner
Snoop testing with all related instruments
20MM Grande, termination cable
dressing, Cable Tray, Breaker wit phases
Motor connection star delta removing and new connection, Isolator switch connection and checking
Ensures and certifies that Calibrations, and trip setting of all field / control room instruments, Analyzers, detectors and laboratory equipment are performed correctly, in time as per safety/ quality and environmental; procedures.
Executes maintenance jobs and performs modifications work on field instruments, Analyzers, Gas detectors,
Laboratory instruments, workshop test equipment’s, Undertakes Trip checking
Carried out Various tests of Control Panels i.e., Cold Test, Hot Test, FAT, SAT etc.
Performed various tasks of Cable Selections, Laying and Terminations.
Knowhow of PLC Programming (Siemens, Fatek, Mitsubishi)
Knowhow of HMI designing for various Control systems.
Carried out Trouble shooting for PLC Based Control Systems.
Worked on Lube Oil Purifier made Mitsubishi and also have hand on experience on its plc.
Performed Preventive Maintenance, Periodic Maintenance, break down Maintenance, Predictive Maintenance and Corrective Maintenance
Troubleshooting of Instruments and Control system for Polymerization, Process, product lines, Utilities Plants
Work on Process variables like Level, Flow, Temperature and Pressure.
Worked on Flow Meters, Orifice Plates, Level Switches, Pressure Switches RTD’S,
Thermocouples, etc
Worked on Power House Gas Engines (Jenbacher 3MW) and different HFO
Engines made Shinko 2MW, Daihatsu 2MW and worked on Power House instrumentation including Pressure Switches, Temperature Switches and Flow Switches.
Izhar Chemical Control Valve ), Nestle Foods (Temp. controller and sensor)Amco
Paints ( Inst. of Inverter for molding )
Fine Arts
URL removed due to policy violation. Please contact support for further information.