RESPONSIBILITIES: I take a part of maintenance team, as an Sr. Electrical Technician/Supervisor now is responsible to carry out all activities under HSE compliance & SOP, s to ensure smooth operation & prevent downtime. Testing, commissioning, startup, PM, CM & faults finding of electrical systems & equipment's of plant, which includes but not limiting to the following:
Gas Turbines 3 x 23.5 MW Rolls Royce (Generator-Peebles) at Plant Bhit Gas Field.
Gas Engine Units 10 x 664 KW GE-Jenbacher (Generator-Stamford) at Wellheads for FEC.
Emergency Diesel Generators 67 KVA to 1.8 MW (CAT, Cummins, Volvo).
Switchgears: 11KV, 3.3KV & 415V (Areva) and 415V MCC (ABB).
Breakers: Alstom VCB Trolley Type for 11KV Bus 3150A, Alstom Vacuum Contactors Trolley Type for 3.3KV Bus 3000A, ABB & Alstom ACB Draw able Type for MCC 415V 2500A.
Protection Relays: For Generator Protection SR-489GE (Envervista), Feeders Management Relay P141 MICOM, Motor Management Relay P241 MICOM, Differential Relay MCAG34 AREVA, Motor Protection Relay Gemstart AREVA, E3Plus AB & UMC-22FBP ABB.
Transformer: Siemens ONAN Type 11/3.3KV 8MVA, 11/.415KV 2MVA, 3.3/.415KV 1.6MVA.
MV Motors: ABB 6.2 MW at 11 KV, Schorch 970 KW & ABB 315 KW at 3.3 KV.
LV Motors: WEG, ABB, SIEMENS, Up to 250 KW at 415V and overhauling of LV Motors.
VFDs & Soft Starter (Allen Bradley & ABB).
RTU (Remote Terminal Unit) for communication interfacing with DCS (Areva).
PLC (Allen Bradley Studio 5000, B&R Automation).
UPS: GUTOR UPS 60KVA & 40KVA for plant and CONVEL UPS 7.5KVA for wellheads.
DCP: GUTOR DCP 21.8 KVA & 17.4 KVA (for Substation 110V DC Power).
Batteries: Lead Acid, Nickle Cadmium, Up to 200Ah, for UPS, DCP & Different Engines.
Fuel Has Heater: 35KW/415V fuel gas heater thyristor control panel (EXHEAT).
Lighting System: Lighting fixture emergency/non-emergency 2x18W/2x36W & Floodlights.
Cables (Testing, Laying, Glanding, Connection & Disconnection of power and control cable).
Workshop Equipment’s: Welding machine, Lath Machine, Drilling & Cutting Machine, etc.
PA System.
Physical Condition Monitoring of Electrical Equipment’s (I.e. Motors, Generators, Transformers, Switchgears, UPS & Other electrical equipment’s) through checklist job plans.
Performed Relays Testing (Micom P241, P141 & MCAG-34) in Coordination to Schneider Electric Pakistan in Annual turnaround of Plant, using CMC-356 OMICRON.
Performed Breaker Testing (Alstom VCB Trolley Type 11KV, 3150A) in Coordination to Schneider Electric Pakistan in Annual turnaround of Plant, using CPC-100 OMICRON, VIDAR and Circuit Breaker Analyzer Test set (GKC-H).
Dielectric Testing of Transformer oil by utilizing dielectric tester, further coordinating with Vendor “Prescon” for DGA analysis from Doble USA.
Participated in commissioning of Booster Compressor (GE SUPERIOR Gas Engine 12SGTD & Camron Compressor) at wellheads, Powered by Brushless Alternator to UCP.