electric engineer supervisor
holding company for water and wastewater
Total years of experience :17 years, 8 Months
electric engineer (operation & maintenance supervisor water sector)
* carry out the requirements of management Quality GERMAN TSM (Technical Sustainable Management) certificate. Fulfill all the requirements & conditions.
Provide solutions to decrease cost of production include energy saving, improve production plan, decrease cost of maintenance through depending on management programs.
Supervise the operation & maintenance performance of potable water plants.
Member of generator working group, to check, set specification, technical support.
Studying illogical solutions for decrease cost like using of solar energy instead of local electric feeder.
FLY WHEEL is a company of generator services. Rent, operating, maintenance, spare parts supplier.
Responsible for Scimitar oil field project (generator service agreement).
Maintenance Electrical Generator especially in caterpillar generator type.
Replace and connect new signal wiring in caterpillar 3704 generator.
Install the March and sensors for caterpillar 3812, 3804 generator.
Fix and troubleshoot some technical trouble in caterpillar 3812, 3804 generator.
Sales manager for maintenance sector.
For Obour potable water plant: 660, 000 m3/day, 350 staff worker, 3 separate product sites -
1 intake raw pump station: 12 pumps Q 5050m3/hour, with motor 1700 kw 3300 volt, startup system ( resistance & soft start ), 2 generator 4.5 MVA, 3 transformer 6MVA, anti-hummer system, mimic panel .
2 Booster raw pump station: the same as intake pumps station but with motor 1250 kW 3300 volt, generator 2.5MVA
3 Main potable water plant: (3) production lines, 4 sedimentation qualifier, 8 rabid sand filters, dosing chemical building, 20, 000 m3 reservoir tank- For each line. Booster filter pump station 9 pumps, mimic panel.
Carry out the preventive and corrective maintenance activities for all field equipment.
The main Responsible about computerized maintenance management system CMMS in the Obour plant
Covering and coding for all equipment in the field, enter data in CMMS program to get work order and maintenance cost.
Electro - mechanical Asset management from maintenance history.
Maintenance safety equipments like fire alarm system, chlorine leakage system, residual chlorine etc.
Maintenance medium voltage equipments. Maintenance transformer, switchgear, motor, etc. (troubleshooting, preventive and corrective maintenance activities).
Check and test new medium voltage panel, transformers, motors and soft starter.
Supervise the install of new pumps group.
Maintenance Schneider medium voltage panel and circuit breaker.
Carry out the requirements of management Quality GERMAN TSM (Technical Sustainable Management) certificate. Fulfill all the requirements & conditions.
( part time )
Fuji electric company is big company in electric component D&C.
ALPHA Group Company is Egypt FUJI sole agent,
Working as main distribute in power section.
Electric contactor, overload, MCCB, inverter… Etc. Main distributes product s.
Studying the inquiring, Tenders and price offers choose the suitable component specification.
Set and Prepare the operating plan (scheduled the facility equipment and process operation)
Set the S.O.P (standard operational procedures) and to ensure that the activities in each operational process follow the S.O.P.
In charge of 50 workers, manage the operating plan, analysis the monthly reports and performance indicator and reduce the product cost procedures.
Technical office engineer
Design and sales for low voltage panels (Technical studying for tenders and offers).
B.Sc.Electrical Engineering. Dates of graduated : MAY, 2006 Al-Azhar University, Cairo. Power & Electrical machine sec. Good / 73.2%. Graduation project / Control of reactive power using artificial neural network. Excellent / 97%.