Mohammad Badrudduja, Instrument technician

Mohammad Badrudduja

Instrument technician

Saudi arabian kentz

البلد
الكويت - الأحمدى
التعليم
دبلوم, Instrumentation
الخبرات
10 years, 6 أشهر

مشاركة سيرتي الذاتية

حظر المستخدم


الخبرة العملية

مجموع سنوات الخبرة :10 years, 6 أشهر

Instrument technician في Saudi arabian kentz
  • المملكة العربية السعودية - الجبيل
  • مايو 2010 إلى أبريل 2013

• Loop checking, pre-commissioning and commissioning of various types of instruments like Smart type Transmitters of Rosemount, Yokogawa, Honeywell, Foxboro and control valves of Fisher, Masoneilan, Azbil and ESDV’s of Biffy .
• Involved in all field Survey works in process units for equipment details, existing installation, existing wiring for Control Room Panels / Equipments, Local Control Panels / Junction Boxes, Field Instruments and Cable Routing.
• Site survey preparation and updates for P&ID, Instrument loop Diagrams(ILD), Control Valves, Motor Operated Valves (MOV) and Shutdown valves, Pneumatic & Electronic Transmitters and Switches, Junction Box Details, Hook-up Drawings, Control room layout for various modification jobs etc.

• Servicing and calibration of Smart type transmitters, Thermocouple, RTD, Temperature controller, Pressure switches, Level switches, SOV’s, Positioners, Booster relays etc.

• Calibration of Level trolls like Tokyo Keiso FST-3000, ABB, Fisher, Masoneilan, Magnetrol etc.

11-09-12 Till Instrument supervisor في KOC
  • الكويت
  • مايو 2010 إلى سبتمبر 2012

Employer: KOC (Kuwait Oil Company) through Kharafi National
Country: Kuwait
Field/Area: Gathering Centre (GC), Instrument Workshop & Crude Oil Wells.
Duration: 30-May 2010 to 10-09-12 Senior Instrument Technician

Position: 11-09-12 Till Instrument supervisor

JOB RESPONSIBILITIES:
• As Instrument supervisor I have involved in the planning of Instrumentation maintenance projects, assignments and related various aspects of projects.

• Provided Lead direction to subordinate personnel, technicians and fitters in the absence of Supervisor; may be assigned standby or call-out status as needed

• Provided accurate and timely input to the company maintenance records or other maintenance information system (s) as required.

• Coordinate with the maintenance Site Coordinator on requirements in the field.
Reporting daily to the Company Site Representative.

• Carried out Preventive, Corrective/Breakdown, and Shutdown maintenance, Start-up activities.

• Carried out calibration and maintenance servicing of all types of field instruments like Smart type transmitters of Honeywell ST 3000, Rosemount 3051 & 1151, Foxboro (IDP 10 series pressure transmitter, RTT 20 series temperature transmitter), Yokogawa (EJX &EJA-E series of pressure transmitters, Yokogawa YTA 110, 310, 320, 50&70 series temperature transmitters) and Eclipse 705 Guided Wave Radar Level transmitters, Flange type level transmitters of ABB, Foxboro etc.

• Calibration and installation of Thermocouple, RTD, temperature Controller, Flow sensors, Pressure switches, Level switches, SOV's, Self regulating pressure regulators, Fuel gas governor valve etc.

• Calibration of Level trolls like Tokyo Keiso FST 3000, ABB, Fisher, Masoneilan, Magnetrol used for Interface measurement of Crude and Water Separation.

• Carried out maintenance, repair and calibration of hydraulic pressure gauges, such as pump pressure gauges, Differential Pressure gauges, casing pressure gauges, manifold mounted gauges etc

• Servicing and calibration (through Positioner) of various types of control valves like Fisher, Masoneilan, ABB Kent Introl and SMART type positioners like Fieldvue DVC 6000 series, Yokogawa YVP 110 series, Siemens SIPART PS2, ABB TZIDC-200, Ecardt etc. and pneumatic positioners of Fisher, Masoneilan, Kent Introl etc.

• Carried out Calibration of instruments through Smart Field Communicator (SFC) and HART 375 & 475 communicator, ABB communicator

• Overhauling and repairing of Well Head Control Panels - Pneumatic type- Delta, Baker, WOM, Hydraulic Type- Cameron Willis in workshop and at wells.

• Routine check and re-installation of solar panels, SSV (Surface Safety Valve) control panels in Marrat wells at KOC East Oil Field.

2. JOB PROFILE

Senior Instrument Technician في Saudi Arabian Kentz
  • الهند
  • يناير 2006 إلى أكتوبر 2009

Employer: Saudi Arabian Kentz
Country: Kingdom of Saudi Arabia
Field/Area: Commissioning Project of SIPCHEM (Saudi International Petro Chemical)
Duration: 20-04 2006 to 13-10-2009
Total Years: 3 & ½ year

Position: Senior Instrument Technician
JOB RESPONSIBILITIES:
• Loop checking, pre-commissioning and commissioning of various types of instruments like Smart type Transmitters of Rosemount, Yokogawa, Honeywell, Foxboro and control valves of Fisher, Masoneilan, Azbil and ESDV's of Biffy
• Involved in all field Survey works in process units for equipment details, existing installation, existing wiring for Control Room Panels / Equipments, Local Control Panels / Junction Boxes, Field Instruments and Cable Routing.
• Site survey preparation and updates for P&ID, Instrument loop Diagrams (ILD), Control Valves, Motor Operated Valves (MOV) and Shutdown valves, Pneumatic & Electronic Transmitters and Switches, Junction Box Details, Hook-up Drawings, Control room layout for various modification jobs etc.

• Making of Loop folders and preparation of punch list & as built in diagrams for loop checking.

3. JOB PROFILE

Employer: Consolidated Contractors International Company (CCIC)
Country: Sultanate of Oman
Field/Area: Oman India Fertilizer & Sohar Refinery, Oman

Instrument Technician في Saudi Arabian Kentz
  • المملكة العربية السعودية
  • فبراير 2004 إلى نوفمبر 2005

Duration: 21-02-2004 to 20-11-2005
Total Years: 21 Months

Position: Instrument Technician
JOB RESPONSIBILITIES:
• Loop checking, pre-commissioning and commissioning of various types of instruments like Smart type Transmitters of Rosemount, Yokogawa, Honeywell, Foxboro and control valves of Fisher, Masoneilan, Azbil and ESDV's of Biffy
• Involved in all field Survey works in process units for equipment details, existing installation, existing wiring for Control Room Panels / Equipments, Local Control Panels / Junction Boxes, Field Instruments and Cable Routing.
• Site survey preparation and updates for P&ID, Instrument loop Diagrams (ILD), Control Valves, Motor Operated Valves (MOV) and Shutdown valves, Pneumatic & Electronic Transmitters and Switches, Junction Box Details, Hook-up Drawings, Control room layout for various modification jobs etc.

• Servicing and calibration of Smart type transmitters, Thermocouple, RTD, Temperature controller, Pressure switches, Level switches, SOV's, Positioners, Booster relays etc.

• Calibration of Level trolls like Tokyo Keiso FST 3000, ABB, Fisher, Masoneilan, Magnetrol etc.


4. JOB PROFILE

Instrument Technician في CCC-SAIPEM, CONSORTIUM
  • كازاخستان
  • يناير 2002 إلى أكتوبر 2003

Employer: CCC-SAIPEM, CONSORTIUM
Country: KAZAKISTAN
Field/Area: KMWC Project.
Duration: Jan 2002 - Oct 2003
Total Years: 20 Months

Position: Instrument Technician

JOB RESPONSIBILITIES:
• Calibration and commissioning of various types of instruments like Smart type Transmitters of Rosemount, Yokogawa, Honeywell, Foxboro and control valves of Fisher, Masoneilan, Azbil, Biffi etc.

• Calibration of Level trolls like Tokyo Keiso FST 3000, ABB, Fisher, Masoneilan, Magnetrol etc.

• Servicing and calibration of Smart type transmitters, Thermocouple, RTD, Temperature controller, Pressure switches, Level switches, SOV's, Positioners, Booster relays etc.

• Servicing and calibration of various types of control valves like Fisher, Masoneilan, ABB Kent Introl and SMART type positioners like Fieldvue DVC 6000 series, Yokogawa YVP 110 series etc.

• Site survey preparation and updates for P&ID, Instrument loop Diagrams (ILD), Control Valves, Motor Operated Valves (MOV) and Shutdown valves, Pneumatic and Electronic Transmitters and Switches, Junction Box Details, Hook-up Drawings, Control room layout for various modification jobs etc.

• Worked as a DCS, PLC console operator in Satellite Instrument House (SIH) for loop checking and commissioning etc. Carried out making of Loop folders and preparation of Punch list.


PRE-COMMISSIONING & COMMISSIONING EXPERIENCE:
• Involved in Loop checking, Pre-commissioning, Commissioning, Logic and sequence test Associated with cause and effect indications.
• Motor Control Center loops.
• Installation, setting gap voltage, Loop checking and cause and effect of radial and axial vibration probes which is made by Bentley Nevada, Series 3500.
• Referred drawings such as hookup, P&ID, Wiring diagram, Layout, Isometric etc
• Making of loop folders and preparation of punch list & as built in diagrams. Good knowledge with Distributed Control System Invensys Foxboro & Triconex PLC & ESD.


CONTROL SYSTEM EXPERIENCE:
• Invensys DCS (Foxboro 10.1series): For Loop Checking, Function checking, Commissioning.
• Invensys Triconex PLC: For ESD (Emergency Shut Down Systems) for Loop Checking, Function Testing, Commissioning.
• Honeywell TDC 3000 for Operation & Maintenance support.

SAFETY TRAINING:
Understand and comply with Safety Case, PTW system and safe working practices and HSE rules.

1. H2S Awareness
2. H.S.E Training.
3. Permit to work (PTW)
4. Electronic Work Permit (EWP)
5. Work at Heights.

الخلفية التعليمية

دبلوم, Instrumentation
  • في Bhagal pur instute
  • يونيو 1997

1. Diploma in Instrumentation. 2. Plus Two. 3. SSLC.

Specialties & Skills

CONTROL ROOM
CONTROL VALVES
FOXBORO
LAYOUT FOR
MAINTENANCE
PRE-COMMISSIONING
SITE SURVEY

اللغات

الهندية
مبتدئ
العربية
مبتدئ
الانجليزية