MECHANICAL HVAC DESIGN ENGINEER
SHAKTHI ENGINEERS
Total years of experience :5 years, 1 Months
HOTEL PALAKKADU project 50 TR (Hyderabad-India)
•Trisha Hotel :Air cooled Chiller plant with 118 TR using Auto-cad (Karimnagar-India )
•VERONA APARTMENT PROJECT 25 TR (Hyderabad-India).
•Residential Complex : Design of split A.Cs using Auto-cad ( Hyderabad- India )
•SAI LOGILLU VILLA PROJECT OF 30 TR IN WARANGAL, TELANGANA.
•330TR Air-cooled Chiller Care Banjara Hospital, Hyderabad, India.
COMPUTER KNOWLEDGE:
HVAC Design Software:
Heat Load Software:
Sizing Software:
Equipment Selection Software:
Carrier Block Load
Mcquay Duct Sizer
Zamil
HAP
Mcquay Pipe Sizer
Evaporator Coil Selector
Elite
Beta Terminal Device Sizer
Blower/Fan Selector(ESP Calculation)
E-20 Form
Expansion Tank Sizer
General Form
Psychometric Chart Analyser
TECHNICAL EXPERTISE:
DESIGINING KNOWLEDGE IN HVAC:-
•Heat load calculation using HAP.
•Calculation duct size using duct calculate, MC QUAY Duct size.
•Finding grills and diffuser sizing using BETA Performance software.
•Chilled water piping Head Calculation.
•Selection of blower fan using External static pressure (ESP).
•Duct design using with MC QUAY DUCT SIZER.
KEY ACTIVITIES:-
•With using HAP software 4.5 versions find out CFM & TON’s.
•With using ASHARE 62.1 table.
•Find out the ESP for blower fan capacity.
•Find out the Grill sizes & Diffuser sizes with using BETA SOFTWARE.
•Duct sizing with using MC QUWAY DUCT SIZER.
•Chilled water piping with using MC QUWAY PIPE SIZER.
•Hydraulic calculation’s to find the pump capacity.
•Preparation of Toilet Exhaust system.
•Drafting of ducts rectangular, round, oval, spiral as per the duct size.
• Primary and Secondary pumps has installed for chilled water supply and return.
•Preparation of duct sections & layout’s.
•Exhaust fan selection & car parking ventilation.
•Calculating the kitchen hood sizes as per requirement of the cooker.
•Drafting experience in the field of HVAC providing air handling unit (AHU) package unit system, ducting and variable air volume(VAV)with Thermostat, supply air diffuser, linear slot diffuser, supply air grills etc.
•Preparation of Linear slot diffuser and grills as per the company standards.
•Preparation of ducting according to design drawing.
•Planning & scheduling of drawings to be submitted in dates to the client.
•Routing of ducting according to availability of space.
(
(