Quazi Rizwan, Distribution Engineer C

Quazi Rizwan

Distribution Engineer C

Saudi Electricity Company

Location
India
Education
Bachelor's degree, Electrical, Electronics and Power
Experience
15 years, 8 Months

Share My Profile

Block User


Work Experience

Total years of experience :15 years, 8 Months

Distribution Engineer C at Saudi Electricity Company
  • Saudi Arabia - Mecca
  • My current job since September 2013

 Switching operations for 33/13.8 kV Main Distribution Equipment and feeders.
 Perform equipment switching out operations and restoring for equipment maintenance.
 To controlling the system through SCADA using Siemens and AREVA software.
 Issuing Work permits, tags and clearances and cancelling the permits after work completion considering the electrical safety of field operators with regular check of CAT-4 and PPE.
 Continuous Monitoring feeders and load depending upon loading of corresponding feeder according to its limits.
 Informing any abnormality corresponding to substation to respective department either maintenance or protection.
 Close loop testing of New Substation.
 Preparing failure reports in SAP notifications for cable faults.

Project Engineer at Mavin Power and Switchgear
  • India - Mumbai
  • May 2012 to July 2013

As Project Engineer:-
• Worked at Jeur, Maharashtra for erection of 220/132/33KV, 100 MVA Transformer Plinth/foundation.
• Responsible for the Completion of projects within the stipulated time & resources.
• Determines appropriate revenue recognition, ensures timely and accurate invoicing, and monitors receivables for project.
• Ensured project documents are complete, current, and stored appropriately.
• Ensured site documentation is properly archived at Head Office at the end of every stage of the project.
• Looked after shifting of 132 KV capacitor bank and cable trenches.
• Procurement of material like control cables (2C, 7C, 12C & 19C) and it’s laying, metal, steel, cement & Sand at site.
• Monitored and Managed & maintain project status reports (Daily, weekly & monthly).
• Responsible for resources needed at site and assigns individual responsibilities to site engineer & supervisor.
• Handled more than 15 workers and supervisor

Asst Manager at Delhi Airport Metro Express Pvt Ltd, Reliance Infrastructure.
  • India - Delhi
  • April 2010 to April 2012

•Since April 2010 till April 2012 as Traction Power Controller & Maintenance engineer.
• To isolate and restore supply for the track and In-charge of operations during engineering or non-operation hours; including isolation of the power supply system, de-energisation during non-revenue hours, imposing track possessions and coordination of line side and non-line side worksites
• To Monitor and control of power network and traction power supply feed from substation (66KV, 33KV, 25KV & 440VAC)
• To Prepare Reports of Daily shift progress, Power Blocks, emergency blocks, Supply Failure record, staff movement record.
• Take-over / hand-Over the system to / from the Chief / Other Controller between operation and engineering hours.
• To issue Power Blocks to Authorized Person / Engineer Possession to work on track during non-revenue hours.
• To plan for periodic maintenance as per Power System and Installation representative requirement.
• Coordinate and keep the OCC Manager, Chief Controller, Train Controller, and Other controller informed in the event of a failure and during the take-over and hand-over of the shift charge, start-up and shut-down of service each day.
• Liaise between the operations team and maintenance staff management in respect to safety or service related failures and incidents.
• To ensure operation of Tunnel Ventilation Fans during Operation, Maintenance hour and emergency condition by coordinating with environment controller.
• Control of engineering activities requiring special trains like RRV & CMV during Emergency condition, track possessions, temporary isolation of equipment etc.
• Periodic Maintenance & Operation of 66/33/25 KV GIS Breaker’s/Panels along with 66/33kV, 66/25kV & 33/0.415kV transformers at Receiving Station.
• Routine Maintenance of Battery Bank, ACDB & DCDB & LT Panel Gas Flooding system.
• Preparing of maintenance program & staff shift duty roaster.

Asst Manager at Reliance Infrastructure
  • India - Mumbai
  • August 2008 to April 2010

Worked as Operation Controller in SCADA Control Room to monitor, analyse, operated, load flow control using SCADA for Mumbai Suburbs.
Department: -
• To controller the system through SCADA.
• Continuous Monitoring and Controlling of all the electrical parameters of the entire network of RELIANCE ENERGY Mumbai electricity distribution system (1598 MW, 5200 S/S) with more than 30lac (HT & LT) consumers.
• Monitoring feeders and load balancing depending upon loading of corresponding feeder.
• Using DMS at substation level for load relieving and during isolation and restoration of supply at time of fault.
• To Isolate the faulty sections and restore the supply within shortest possible time for 33/11/0.415KV Cables.
• Operations for planned & breakdown maintenance.
• Coordinate and keep the MCC Manager and Other controller informed in the event of a failure and during the take-over and hand-over of the shift charge.
• To prepare database of the breakdown & outages, and daily progress reports.
• Maintaining voltage limits at Receiving Stations and also maintaining PF at receiving end.
• Planning Preventive maintenance of 33KV/22KV/11KV RMU Switch Gears and carrying out its load transfer operations, also for Power Transformers OLTC maintenance outages.
• Network Studies for improvement of existing Distribution system.
• Laying of Cable, Fault detection by pick up method.
• Erection of 11/0.415kV RMU in Mumbai Suburbs.

Education

Bachelor's degree, Electrical, Electronics and Power
  • at Goverment Collage of Engineering Aurangabad
  • July 2008

Passed from Government Engineering College Aurangabad. Major Subjects- Electrical Generation transmission and Distribution, Renewable energy, power electronics, Electrical Installation. Machine Design. Network Analysis

Specialties & Skills

Electrical Maintenance
Load Dispatcher
Equipment Maintenance
Construction & Property
MS Word
MS Word
Traction Power Control
Operation and Maintenance
Electrical Operations
Distribution Enginer

Languages

English
Expert
Hindi
Intermediate
Marathi
Intermediate
Urdu
Intermediate
Arabic
Beginner
Arabic
Beginner