shaihid anwar, Worked as a Consultant Electrical

shaihid anwar

Worked as a Consultant Electrical

SATECH

Location
Pakistan - Lahore
Education
Bachelor's degree, Electrical(Communication)
Experience
9 years, 6 Months

Share My Profile

Block User


Work Experience

Total years of experience :9 years, 6 Months

Worked as a Consultant Electrical at SATECH
  • Saudi Arabia
  • September 2012 to February 2013

Worked as a Consultant Electrical (Electrical Engineer) from Sep 2012 to Feb 2013 at Saudi Technologist Consulting Engineers (SATECH) on Saudi Electricity Company (SEC) Projects,

Key responsibilities are:
Consultant Electrical:
➢ Provide consultancy of Electrical works for 110/13.8KV Substations.
➢ Provide Consultancy and Client Side Management and Supervision Services.
➢ Responsible for project control procedures, logical scheduling, progress monitoring, QA/QC and OHSE application and awareness.
➢ Supervise that the erection and commissioning work is done at substation as per given Saudi Electricity Company (SEC) standard.
➢ Make sure that the materials/equipments used at site are as per given specifications/ Standard.
➢ Examine and control the construction activities related to Electromechanical installation.
➢ Provide contribution to prepare logical Construction Schedules and administration of Safety/ Loss Prevention activities.
➢ Assessment of design review, if needed, as per Project Technical Specifications and Technical Engineering Specifications.
➢ Review and certify "As Built" Drawings prepared by contractor's team and to ensure the accuracy and compliance.
➢ Arrange weekly, monthly and annual progress meeting to complete work within scheduled time period.

Electrical Engineer at Saudi Bin Ladin Group
  • Saudi Arabia - Jeddah
  • April 2011 to September 2012

Construction Engineer:
 To supervise installation and Termination of M.V panels such as Medium Voltage Switch Gear (MVSG) controlling panels.
 To supervise installation and Termination of Power Transformer (13.8/0.4 KV) and Power Cables.
 To supervise installation and Termination of L.V Cables/Panels such as MDB, MCC, MCP, DP, ATS, Power Panel, Lighting Panel, UPP, Capacitor Bank etc.
 To supervise installation of all electrical wiring inside and outside the building such as Lighting, Power, VAV, CAV, AV, EO etc.
 Installation of Earthing and Lightening protection System.
 The solution of different problems between Electrical, Mechanical, Civil and Low Current by coordination meetings.
 Monitor material supplies and its conformity to the required specifications.

QA and QC Engineer:
 Here, I also performed the duties of QA & QC Engineer.
 Making sure of all Electrical Installation as per given standards.
 Generate and approve RFI from consultant (Dar Al-Handasah).
 Creates snag lists of balanced work in entire building.
 Complete the balanced work as per given description.

Operation & Maintenance Engineer:
 I also performed the duties of operation &maintenance engineer.
 I have also performed the duties as a Team Leader (Operation & Maintenance Electrical) in buildings names as Ambulatory Care center, Cardio Vescular Centre, Ancilary Building, Medium Voltage switch Gear Building, Domestic Water Tank, Generator Building etc.
 Independently to execute the maintenance team for troubles shooting, repair or day by day maintenance activities.

Grid Station Incharge at Lahore Electric Supply Company
  • Pakistan - Lahore
  • July 2005 to April 2011

Worked as a Grid Station Incharge (SSO-1) from July 2005 to Apr 2011 at 132KV Grid Station New Airport Lahore, in Lahore Electric Supply Company (LESCO),
Key responsibilities are: ➢ Construction, Commissioning, Operation, Maintenance and Protection/Testing, of 132KV/11KV Sub Station/Transmission Line system.
➢ Operation and Maintenance of all Grid Station Equipments such as 132KV control panels, 11kv control panels, circuit breakers, CT, PT, rectifier, earth mesh etc.
➢ Check and Maintain voltage level (11.5KV), Load (A), Oil level, and Temperature of power transformer and SF-6 gas pressure in 132KV bus bar (GIS) system.
➢ Checking of DC batteries gravity, electrolyte level, terminal voltage, voltage stability, load (AH), and temperature and maintaining DC supply.
➢ Electrical Switching, Relay Testing/Calibrating, Meter Testing/ Calibrating, Isolation and De isolation, Electrical Drawing.

➢ Power Transformer Protection system.
Over current protection, Earth fault protection, Differential protection, Buchhloz relay protection. Over temperature protection etc.
➢ 132KV/11KV Switchgear control panel protection system.
Over current relay protection, Earth fault relay protection, Distance relay protection.
➢ 132KV/11KV Line protection system.
Distance Relay (Impedance Relay) protection system, Over current protection. Earth fault protection system, Differential Protection, Earth leakage resistance protection.
➢ Arranging different types of protection and safety tests for different protection equipments at Grid Station.
Power Transformer Tests •Insulation resistance (Megger) test, Oil DES test, TTR test, C& DF test, Moisture test.
132KV/11KV Circuit Breakers Tests• Contact resistance test, Breaker opening closing time test, Insulations resistance test, Vacuum test, Hipot test, Vadal test, Dielectric strength test, Refilling of SF-6 Gas.SF-6 Gas pressure test.
11KV Power line Tests • Moisture test, Insulation test, Capacitance test, Hipot test.

Electrical Supervisor in Hafeez Shafi Tanneries at O&M of Genset
  • Pakistan - Lahore
  • February 2002 to November 2003

Worked as an Electrical Supervisor in Hafeez Shafi Tanneries, from February 2002 to November 2003.
Key responsibilities are: ➢ Supervise and Manage all Electrical related problems in tannery.
➢ Installation and maintenance of lather processing machines.
➢ Maintaining Supply of power for the factory using WAPDA connection and Genset, refueling of Genset, O&M of Genset.

Education

Bachelor's degree, Electrical(Communication)
  • at Institute Of Engineering and Technology Lahore
  • January 2005

Bachelor of Engineering 2001-2005 Institute Of Engineering and Technology Lahore. 1st Div.

Diploma, Computer Application
  • at S.S Memorial College of Computer Sciences Sahiwal
  • August 2004

Diploma in Computer Application Aug, 2004 S.S Memorial College of Computer Sciences Sahiwal. 1st Div.

High school or equivalent, Electronics
  • at GCT Second Campus Lahore
  • January 2000

D.A.E (Electronics) 1997-2000 GCT Second Campus Lahore. 1st Div.

High school or equivalent, Science
  • at Federal Government Abid Majeed High School LHR
  • January 1997

Matriculation (Science) 1996-1997 Federal Government Abid Majeed High School LHR. 1st Div.

Specialties & Skills

Electrical Engineering
Consultant Coordination
CALIBRATING
CLOSING
CONTROL PANEL
DRAWING
MAINTENANCE
RELAY TESTING
TESTING

Languages

English
Expert
Arabic
Intermediate