Quality controller
DUCAB
مجموع سنوات الخبرة :15 years, 5 أشهر
Testing of cables including low, medium &high voltage up to 220kv as per BS & IEC standards
Testing of instrumentation cables including pair, quad & traid cables as per BS 5308-1, BS 5308-2.BS EN 50288-7
Test of pilot cables including jelly filled cable
Conducting tests on samples drawn from incoming raw materials as per the procedures and preparing test reports.
Conducting in-process and final checks and tests on samples as per the laid down procedures and reporting results to appropriate personnel.
Maintaining records of various checks and tests conducted.
Periodic audit of key processes and random check reports to be made available on the network.
Involved in BASEC, LPCB & KEMA Audits
Recommending process rework in accordance with documented procedure.
Releasing or holding cables after test stamping the test status on Drum cards and maintaining records.
Preparing Cable Test Certificates as and when required by the customer.
Checking cable material weight of the samples drawn from each lot and preparing monthly material give-away report.
Calibrating test equipment as per the laid down procedures and maintaining records of the same.
Calibration of machine meter counters according to plan to ensure correct length of cable at various stages in production.
Analysing competitor's cable samples and prepares report as instructed.
Reporting any product or process abnormalities to the Production Supervisor in the shift and TIE.
Statistical analysis of test results and recommending improvement opportunities to the management.
Carry out testing required in process trials and provide timely feedback to TM for design verification and validation.
Perform analysis of defective cable samples for cause identification for in process defects or as part of customer complaint investigation.
Carry out tests required in customer witnessed inspections and respond to customer questions on the test method/results under supervision.
Precise location of cable faults to minimize loss of faulty cable lengths during manufacture.
Fault location at customer site.
Supervision of end preparation and terminating MV cable end and carrying out Partial Discharge and HV tests on MV cables.
Preparation of Testing Instruction for Ducab.