Work Experience

Total years of experience :16 years, 8 Months

Operational Coordinator at Carillion Alawi LLC
  • Oman - Muscat
  • My current job since July 2013

Responsibilities:
Working as MEP Operational Coordinator and leading a team of 15 to 20 People
Responsible for the reactive and planed preventive maintenance
Responsible to insure PPM of 3 phase induction motors, UPS, Switchgear, Lighting, D.B & Generators
(Monthly, 6 monthly & yearly)
Responsible to insure health and safety as per PDO norms during work
Managing Electrical Shutdown as per PDO schedule
Using GENEVA and SAP software for print out scheduling wise PPM, and reactive job cards.
Follow up outstanding reactive jobs with our subcontractor’s.
Monitoring team and vehicle through IVMS system.

Electrical Technician at Gulf Engraining Service
  • Pakistan - Multan
  • October 2010 to April 2013

Preventive maintenance of medium and low voltage motors. Maintenance & overhauling of 11KV motors. MV motors up to 3MW and LV 380v motors up to 200KW, Overhauling, Termination, rotor and stator cleaning Heating, Meggering, and bearing replacement

• Generator Connection Checking and replacement to Carbon Brushes.
• Generator General Type Bearing Replacement.
• Inlet and Outlet Oil Line Leakage test.
• Rotor & Generator all electrically test.
Winding resistance measurement
Insulation resistance measurement
Polarization index test
Power factor tip-up test
Dissipation factor test
Partial discharge test
• Generator Hydrogen Lines Leakage Test.
• Generator Cooler Cleaning and Leakage Test.
• Excitation Transformer Electrically Test.
• Excitation Panel cleaning and testing with DC Breaker.
• Surge Arrester of Generator Panel Cleaning and Electrically test.
• Turbine HP, IP, LP Upper & Lower Diaphram Seals Replacement.

• DC Distribution Panel Maintenance.
• MCB Breaker, 3 Pole & 2 Pole, Timer, Relays, D.C H.R.C Fuse Kit, D.C Coupler Box Cleaning Maintenance Continuity Test & Mage ring.
• DC Bus Bar Lose Checking.
• Cable Insulation test with continuity test.
• Isolator cleaning and Isolator Panel test with 110V DC Motor.
• Operate the Isolator Manually & Automatically.
• SF6 Circuit Breaker Panel Cleaning & Maintenance.
• SF6 Compressor Motor Checking & Mage ring.
• Change the Oil Compressor Pump.
• AC Distribution Panel checking and cable insulation test.
• Power & Control Cable Laying
• PC & CC Cable Continuity Test & Short Circuit Test
• Power & Control Cable Gladding,
• MCC Panel Installation & Termination.
• Power & Control Cable Termination.
• 11 KV VCB panel Install & Termination.
• DC Motors Install, Termination & Commissioning.
• Cooling Bed Inlet & Outlet DC Motors Install & Termination.

Electrical Forman at SMC (S Mechanical Company) LLC Qatar
  • Qatar - Doha
  • May 2010 to August 2010

MICC (Mineral Insulated Clad Cable) lying & Termination Install the 25mm conduit (Bending, cutting, joint & fitting), Pulling the wire & install the florescent lighting, 2D lights. Install D.B and use MCCB, RCD, and ELCB.Cable Gland and Termination LV/HV Switch Rooms.

Electrical Technician at Dost Still Mill Ltd.
  • Pakistan - Lahore
  • January 2007 to November 2008

Attend the jobs of installed electrical equipment with Testing & Commissioning. Electric LV/ HV Panels, Three Phase & Single Phase wiring, Maintenance Lighting System, LT panels of power house, Installed the Three Phase & Single Phase Motors with D.O.L Starter, Star Delta, Reverse & forward Starter, Installed the D.C Motor, Installed the VCB, ACB, MCC Panels with Termination & Commissioning, worked at cable tray fixed, Cable pulling, Fixed the Conduit wiring, Performed Control Circuit Wiring and Modification on MCC and PCC as per the original drawing / site / Process requirements.

Electrical Technician at WAPDA
  • Pakistan - Multan
  • January 2006 to December 2007

Responsibilities:
Maintenance single & three phase motor. Rewinding single phase motors and pumps
Maintenance work in switch yard, maintenance and cleaning in SF6 circuit breaker with insulator &isolator Testing (manual and automatic operate SF6, change oil SF6 compressor pump) as per as the Electrical Safety rules with PTW System.
Maintenance of the Plant area Lighting (change & Replace fuse lights with safety)
11 KV (VCB) Switchgear panel Annually Maintenance (Electrical test, replace expire VCB bottles & cleaning) all work as per LOTO system.
Protective and corrective maintenance of Power generation equipment including 220 MW Generators
Look after Operation and Maintenance work of Indoor, Outdoor Lighting Protection System

Education

Diploma, electrical
  • at Diploma of associate engineer in Electrical
  • August 2005
High school or equivalent, Science
  • at BISE
  • June 2002

Specialties & Skills

Maintenance Engineering
Electrical Engineering
Preventive Maintenance
Electrical Maintenance
Low Voltage
Computer Opreater
CEP Electrical
MS Office
IVMS Tracking system

Languages

English
Intermediate
Arabic
Beginner
Urdu
Expert
Punjabi
Expert

Training and Certifications

MS Office (Certificate)
Date Attended:
August 2010
H2S (Training)
Training Institute:
TATI Oman
Date Attended:
July 2013
Duration:
48 hours
Fire Fighting (Training)
Training Institute:
NTI Oman
Date Attended:
October 2013
Duration:
48 hours
First Aid (Certificate)
Date Attended:
February 2015
Valid Until:
February 2017

Hobbies

  • Book reading
    I like Islamic stories
  • Plays criket
  • internet searching