Chemist
Sharjha Electricity and Water Authority
مجموع سنوات الخبرة :20 years, 1 أشهر
Capacity of 75MWx4 & 33MW X 4 (Oil & Gas Fired Boiler) & 33 MW X 2 GT & 36MW X 3 GT & 123 X 2 GT (Oil & Gas Fired Boiler) combined steam generation X 7 Units
60MGPD Production with 5 multi stage flash and 4 Multi Effective desalination & RO Desalination
Titrative analysis of different parameters like Boiler feed water, drum water, saturated steam, superheated steam, condensate, raw water, soft water, cooling tower recirculation water
o Chemical analysis of bottom ash, Fly ash.SO2, No3, SPM in chimney, seawater RCB, BBD BHC, distillate, primary condensate, secondary condensate, commute LTA & CF, RO feed water, RO permeate, SDI, RO post treatment water
o ISO audit
o Specific gravity, say blot viscosity, oil in water, water in oil, colour, ash, vanadium, potassium, sodium, acidity, rust preventing test, foam test, flash point, pour point, carbon residue, transformer oil in dissolved gas analysis, lube oil analysis, calorific value determination, sulphur, air release value of lubricating oil, oxidation stability of insulating oil, transformer oil, switchgears, pentane insoluble
• Involving in analysis of lignite, flue gas, sieve, BOD, COD and DO
• Accountable for the preparation of standard solution & calibration of instruments
• Handling the operations of:
o Side stream filter
o Pre-treatment plant
o Cooling water chemical treatment.
o RO Plant through PLC system
o DM Plant through PLC system
o Decanter System
o Sewage Water Treatment Plant
o Effluent Treatment Plant
o Air pre heater wash & GT crank wash
o Acid cleaning in multi stage flash
• Closely monitoring the environmental parameter
• Pivotal in handling the commissioning of R.O plant and DM plant and power plant
• Closely monitoring the condenser leak & handling cation column maintenance
Plant capacity 77MWx2 (PF Fired Boiler) & 80MW X 1
Instrumental &titrative analysis of different parameters like Boiler feedwater, drumwater, saturatedsteam, superheatedsteam, Condensate, Raw water, soft water, Cooling tower recirculation water, Lignite analysis, Flue gas analysis, Sieve analysis, Analysis of BOD, COD, DO.Complete chemical analysis of bottom ash, Fly ash.SO2, No3, SPM in chimney,
Preparation of standard solution & calibration of instruments.
Operation of side stream filter.
Dosing at H.P, L.P.monitoring
Operation of Pre-treatment plant
Cooling water chemical treatment.
Operation of RO Plant through PLC system
Operation of D.M. Plant Through PLC system
Commissioning of R.O plant and DM plant
Plant Capacity of 40MW (FBC Fired Boiler
Instrumental &titrative analysis of different parameters like Boiler feedwater, drumwater, saturatedsteam, superheatedsteam, Condensate, Raw water, soft water, Cooling tower recirculation water, Lignite analysis, Flue gas analysis
Plant Capacity of 210MW X 7 units (TS II, Stage II) (PF Fired Boiler)
Instrumental &titrative analysis of different parameters like Boiler feedwater, drumwater, saturatedsteam, superheatedsteam, Condensate, Raw water, soft water, Cooling tower recirculation water, Lignite analysis, Flue gas analysis, Sieve analysis, Analysis of BOD, COD, DO.Complete chemical analysis of bottom ash, Fly ash.SO2, No3, SPM in chimney,
Preparation of standard solution & calibration of instruments
Responsibilities
•Conducting detailed:
• Titrative analysis of different parameters like Boiler feed water, drum water, saturated steam, superheated steam, condensate, raw water, soft water, cooling tower recirculation water
•Chemical analysis of bottom ash, Fly ash.SO2, No3, SPM in chimney, seawater RCB, BBD BHC, distillate, primary condensate, secondary condensate, commute LTA & CF, RO feed water, RO permeate, SDI, RO post treatment water
•ISO audit
•Specific gravity, say blot viscosity, oil in water, water in oil, colour, ash, vanadium, potassium, sodium, acidity, rust preventing test, foam test, flash point, pour point, carbon residue, transformer oil in dissolved gas analysis, lube oil analysis, calorific value determination, sulphur, air release value of lubricating oil, oxidation stability of insulating oil, transformer oil, switchgears, pentane insoluble
•Involving in analysis of lignite, flue gas, sieve, BOD, COD and DO
•Accountable for the preparation of standard solution & calibration of instruments
•Handling the operations of:
•Side stream filter
•Pre-treatment plant
•Cooling water chemical treatment.
•RO Plant through PLC system
•DM Plant through PLC system
•Decanter System
•Sewage Water Treatment Plant
•Effluent Treatment Plant
•Air pre heater wash & GT crank wash
•Acid cleaning in multi stage flash
•Closely monitoring the environmental parameter
•Pivotal in handling the commissioning of R.O plant and DM plant and power plant
•Closely monitoring the condenser leak & handling cation column maintenance