Independent In charge direct reporting to Project Manager for Electrical & Instrumentation Part of the Project.
Good understanding of the flow and logistics needed for the execution of an EPC project. Deft in reviewing engineering drawings, technical specifications, cost estimates for proposed making for EPC project.
Evaluate Overall project’s Philosophy & Concept (Designing >Engineering >Scope & Spec. of Work>.
Finalized the BOM/MTO as per Tender’s documents.
Coordinate with Client, PMC, TPI, Consultant & Vendors,
Motivate the Entire Execution Engineers Team.
Core strengths in coordinating and directing the project team as well as coordinating and controlling all required project management systems.
Installation, Testing and commissioning of HT/LT Sub Stations, Transformer, Control Panel Power Feeder & Distribution Panel & MCC Panels, HT/LT Motors, D.G Set & UPS System, Lighting System & Earthing Protection & Cabling work etc.
Functional & Scheme checks for 33KV, 11KV, 6.6 KV, 415 V Indoor Switchgear with Interlocks.
Stability & Sensitivity Tests for Transformer.
Familiar with Protection Scheme of Transformer Differential & REF Protection.
Electrical Equipment testing CT, PT, Breaker, Relays, Bus bar.
Carried out the Electrical Testing of transformers such as IR value, Winding Resistance, Turns Ratio, Open Circuit Test (Ratio, Vector Group, No Load Magnetizing Current, and Magnetic Core Balance) & Short Circuit Test (%impedance).
Testing of CTs, VTs and CB.
REC 670 testing and commissioning.
Testing of individual equipments such as CTs, PTs, CVTs, Breakers (SF6/Vacuum), Isolators and Protection relays in 400/220/132/66/33/11 KV Outdoor Substations.
Operation and maintenance of 132/33/11 KV substations substation equipment having SF6 CB, Vacuum CB.
Testing & Commissioning of Battery Bank along with Battery charger of 50 v, 110 v, 220 v systems.
Testing & Commissioning of SOLAR System.
Actively involved in Field Instruments, Process Instruments, Gas Metering Skid, and Flow Meter, Gas Chromatograph.
Automaton & Control System Integration with existing control Network DCS & SCADA
System Integration with DCS, system check with Simulation & testing of trip interlocks in co-ordination with operations.
Overall system functionality & integrity Check, Testing & Commissioning (Conducting SAT).
Calibration, Testing, Loop Check of Process Instruments - Pressure, Temperature, Density, Flow & Level Transmitters.
Conduct the Onsite Calibration of Pressure Safety Valve & Transmitters.
Functional Test of different type Hydro -Pneumatic Actuators Valves & PST Valve.
Functional Test of Flow-Serve Control Valve along with the PID Controller (Reverse Acting /Direct Acting).
Calibration Testing & Commissioning of Hydrocarbon Gas Detector, Flammable Gas Detector /H2 Detector, Heat Detector, Smoke Detector.
Smart Transmitter (HART) Pressure, Temperature, Flow, level (Rosemount, Yokogawa, Foxboro, Honeywell) & Control Valve (Fisher, Emerson, Mestro) Multivariable type transmitters & different type elements, MOV (Rotark), Interface level transmitters (magnetrol) & Pressure Switches.
Pre-Commissioning & Commissioning of Smart Transmitters (HART) (Yokogawa, Rosemount, Foxboro, Honeywell), Control Valves (Fisher, Emerson, Mestro) and Biffi Emergency Shutdown valves, Interface level transmitters (Magnetrol), Motor Operated Valve (Rotark), Mass Flow Meter & Pressure Switches.
Functional Test of Fire Alarm and Gas Detection & Fire Fighting System Co2 Room Flooding System, Inergen System, Springler System & Deluge System.
Cause & Effect Test of Conventional & addressable Fire Alarm Control System.
Monitoring & supervision of Cathodic Protection (CP) System, Installation & Commissioning & Mitigate the Interferences.