فهد بن عودة, Power and Utilities Operator-1

فهد بن عودة

Power and Utilities Operator-1

Ma'aden Phosphate Company

البلد
المملكة العربية السعودية - الشرقية
التعليم
دبلوم, Steam Power Plant Operation
الخبرات
20 years, 8 أشهر

مشاركة سيرتي الذاتية

حظر المستخدم


الخبرة العملية

مجموع سنوات الخبرة :20 years, 8 أشهر

Power and Utilities Operator-1 في Ma'aden Phosphate Company
  • المملكة العربية السعودية
  • أشغل هذه الوظيفة منذ نوفمبر 2012

Power and Utilities Operator-1

Utilities Operator في Saudi Aramco Shell Refinery Company (SASREF)
  • المملكة العربية السعودية - الجبيل
  • يناير 2012 إلى نوفمبر 2012

Saudi Aramco Shell Refinery Company (SASREF), Reforming & Resources Operations Department.
Utilities operation, Boilers produce steam for distribution within the refinery, Boiler Feed Water to the main boilers as well as to other refinery units, collection and treatment of steam condensate in the demin plant, cooling water systems, Instrument air compressors to operate all The control valves on the refinery, power generating system, fire water system and Nitrogen gas system.

•Take check around, make equipment line up and isolation, check plant status.
•Preparing solutions and chemicals as required.
•Tops up injection tanks and adjusts injection rates as instructed.
•Perform operational field activities during Start-Up, Shut-Down and process upsets to minimize plant disruption.
•Directly reporting to the Panel Operator and Shift Manager of any defect in the plant.
•Take samples and analyze it.
•Give work ermit to the maintenance staff.

Steam Power Plant Shift Foreman (Break-In) في Saudi Electricity Company
  • المملكة العربية السعودية - الجبيل
  • مايو 2011 إلى يناير 2012

Saudi Electricity Company - Eastern Region, Ghazlan Power Plant Phase II, Four Units MHI (MITSUBISHI HEAVY INDUSTRIES) Forced Circulation, positive draft, Radiant Reheat type Boiler, 165 barg, 540/540°C Steam condition, 2120 T/H BMCR Main Steam Flow, Oil/Gas Tangential Firing, tilting burner, corner fired design, Four Units Mitsubishi, four cylinders (one HP, one IP and two LP), Tandem Compound, Reheat, Quadruple Exhaust, Condensing Steam Turbine with a Generator up to 700MW power Output each Unit. And a Generator Voltage of 23 kV.

•Assigns duties to CRO’s (Control Room Operator) Operators and oversees department activities: Revises work assignments as required by priorities and work availability. Explains and demonstrates procedures and techniques to CRO’s & Operators. Interprets specifications and work orders for CRO’s & Operators.
•Conduct regular inspection of plant facilities to ensure plant’s correct functioning. Correct malfunction if appropriate or refer situation to the Shift In-Charge.
•Coordinate with maintenance personnel by identifying/locating and demonstrating malfunctioning plant and equipment. Inspect maintenance work if required.
•Responsible for the overall safe reliable and efficient operation of the generating plant auxiliary equipment, in accordance with the company policies Operations Department policies or as directed by the Shift In-Charge.
•Take gas test and ensure the work permit is completed properly in the presence of safety engineer and fireman as per company safety procedure.
•Issue work clearances (equipment hold order) to isolate, release and normalize after maintenance job is performed and Issue Work Permit for Maintenance or Contractor.
•Create maintenance notifications by SAP system, Plant Maintenance, Maintenance Processing in order of report a malfunction at a technical object and request that the damage be repaired.
•Carrying out High Voltage isolations and switching, Rack in/out breakers 13.8Kv, 4.16Kv & 480V.

Steam Power Plant Control Room Operator (DCS Operator) في Saudi Electricity Company
  • المملكة العربية السعودية - الجبيل
  • أبريل 2009 إلى مايو 2011

Saudi Electricity Company - Eastern Region, Ghazlan Power Plant Phase II, Four Units MHI (MITSUBISHI HEAVY INDUSTRIES) Forced Circulation, positive draft, Radiant Reheat type Boiler, 165 barg, 540/540°C Steam condition, 2120 T/H BMCR Main Steam Flow, Oil/Gas Tangential Firing, tilting burner, corner fired design, Four Units Mitsubishi, four cylinder (one HP, one IP and two LP), Tandem Compound, Reheat, Quadruple Exhaust, Condensing Steam Turbine with a Generator up to 700MW power Output each Unit. And a Generator Voltage of 23 kV.

-Monitor the Distributed Control and Information System (DCIS) readings and alarms and take appropriate action to correct deviations from established standards to ensure continuity of operations and provision of electric power in a safe and reliable manner according to load demands.
-Perform daily shift items in accordance with field operator(equipments test, changeover, confirm)
-Check plant Equipments status and monitor it, make equipment line up and isolation.
-Take remedial actions about the developed abnormality, to keep the system working in safe operating mode of ghazlan power plant, phase II.
-Perform the start-up or shutdown of the plant and facilities according to approved operating procedures and general instructions.
-Provide written reports on unit conditions and operations.
-Use PI System Trends to monitor the Operation process, to know the reason of the problem to trouble shoot it and to write report with explaining.
-Monitor processes and identify root causes of problems to reduce unaccounted-for losses.
-Safely operate pumps, compressors, fans and other plant equipment within safe operating ranges.

Steam Power Plant Field Operator في Saudi Electrcity Company
  • المملكة العربية السعودية - الجبيل
  • سبتمبر 2006 إلى أبريل 2009

Saudi Electricity Company - Eastern Region, Ghazlan Power Plant Phase II, Four Units MHI (MITSUBISHI HEAVY INDUSTRIES) Forced Circulation, positive draft, Radiant Reheat type Boiler, 165 barg, 540/540°C Steam condition, 2120 T/H BMCR Main Steam Flow, Oil/Gas Tangential Firing, tilting burner, corner fired design, Four Units Mitsubishi, four cylinder (one HP, one IP and two LP), Tandem Compound, Reheat, Quadruple Exhaust, Condensing Steam Turbine with a Generator up to 700MW power Output each Unit. And a Generator Voltage of 23 kV.

-Take reading, make shift items in accordance with control room operator, and make equipment line up and isolation, check plant status.
-Operate and monitor machinery and equipment of Steam Power Plant and its auxiliaries during the shift, and ensure its smooth operation.
-Directly reporting to the Control Room Operator and Assistant Shift Foreman of any defect in the plant.
-Responsible for the overall safe reliable and efficient operation of the generating plant auxiliary equipment, in accordance with the company policies Operations Department policies or as directed by the Shift Foreman and Control Room Operator.

CNC Machine Operator في East and West Factory for Electric panels & Boards ,A.A.Turki Corp (ATCO Group)
  • المملكة العربية السعودية - الدمام
  • يناير 2004 إلى يوليو 2006

FINN-POWER A5 CNC Hydraulic Turret Punch press (Sheet Metal Punching) Operation, Technician, CNC Program edit, Troubleshooting, Teaching coop Students and Maintenance.
Panels Assemble.

Trainee في East and West Factory for Electric panels & Boards ,A.A.Turki Corp (ATCO Group)
  • المملكة العربية السعودية - الدمام
  • سبتمبر 2002 إلى يناير 2003

FINN-POWER A5 CNC Hydraulic Turret Punch press (Sheet Metal Punching) CNC Engineer Helper.(trainee)

الخلفية التعليمية

دبلوم, Steam Power Plant Operation
  • في Saudi Electricity Company Dammam Training Institute
  • يوليو 2007

Saudi Electricity Company Dammam Training Institute Non Employee Training Program in the Field of Steam Power Plant Operation.2007 GPA 5.00 out of 5.00. Excellent. First honor.

دبلوم, Mechanical Technology (Production)
  • في College Of Technology
  • يونيو 2003

The Associate Degree of College of Technology from the department of Mechanical Technology in the field of Production.(Diploma) Grade C Good GPA 3.08 out of 5

الثانوية العامة أو ما يعادلها, Scientific
  • في Al-Khobar Secondary School
  • يونيو 2000

High School from Al-Khobar Secondary School In TheField Of Scientific.

Specialties & Skills

Utilities operation
Plant Operations
Power Plant Operations
Operation
Operating CNC Machine
Steam Power Plant Operating
READING OF PIPING & INSTRUMENT DIAGRAM
PI System Trends
DCS System Operation
Learn and self improving
Communication
Self-motivation and enthusiasm
Troubleshooting
SAP System

اللغات

الانجليزية
متمرّس
العربية
متمرّس
الالمانية
مبتدئ

التدريب و الشهادات

GPA 5 out of 5. (Excellent). First honor. (الشهادة)
تاريخ الدورة:
September 2006
صالحة لغاية:
July 2007