RADIO and transmission engineer
ZTE Coorporation
Total years of experience :11 years, 10 Months
Installation & Commissioning of all type MW Antenna (0.6m, 1.2m, 1.8m, and 2.4m) .
• Swap, Installation and Integration of 2G, 3G and LTE Technologies and Microwave Transmission
• Installation of BTS, Indoor, Outdoor
• Integration of BTS Sites
• Site Integration manually and by Using WDT Software of Huawei and ZTE .
• Downloading software, Script, configuring and removing components using LMT for ZTE.
• Antenna cutover and sector addition, new outdoor Site Installation and Commissioning.
• Dismantling of Existing BTS, MW-hope, IDU, ODU, Antennas & Accessories
• VSWR Measurements & Alarm rectification of Existing cell sites
• Self-Assessment of installed site
• Site Documentation & inventory management
• Quality Work and Acceptance Test PAT.
• TRX Addition with New and Existing sites.
• DTRX Segmentation
• Installation of GSM and CDMA Antennas.
• Installation and testing PS (power supply).
• Test KPI
Installation & Commissioning of all type MW Antenna (0.6m, 1.2m, 1.8m, and 2.4m) .
• Swap, Installation and Integration of 2G, 3G and LTE Technologies and Microwave Transmission
• Installation of BTS, Indoor, Outdoor
• Integration of BTS Sites
• Site Integration manually and by Using WDT Software of Huawei and ZTE .
• Downloading software, Script, configuring and removing components using LMT for ZTE.
• Antenna cutover and sector addition, new outdoor Site Installation and Commissioning.
• Dismantling of Existing BTS, MW-hope, IDU, ODU, Antennas & Accessories
• VSWR Measurements & Alarm rectification of Existing cell sites
• Self-Assessment of installed site
• Site Documentation & inventory management
• Quality Work and Acceptance Test PAT.
• TRX Addition with New and Existing sites.
• DTRX Segmentation
• Installation of GSM and CDMA Antennas.
• Installation and testing PS (power supply).
• Test KPI
Ensure that project handover from construction to commissioning and to operations (client) are carried out and documented in accordance with company procedures.
Follow up that the installation / construction has been completed in accordance with the engineering packages and technical requirements.
To check that works performed by the subcontractor conform to design documents, Safety regulations, and to the Quality.
Installation and commissioning of electrical transformers ( 400kv/33kv, 33kv/6.6 kv and 33kv/400 v).
Electrical and mechanical test of breakers and insulator 400kV, 33kV, 6.6kv, 0.4 k
Installation and commissioning of electric cells (33 kv, 6.6kv)
Perform experiments on Protection and control relays ( REF 615, RET, RED….)
Commissioning of and start up of substation electrical equipments: Current transformer, Voltage transformer, Breaker, Insulator, MV cable (Insulation and HiPot Test), Battery Charger, and Battery’s (Charge and discharge Test).
Verifies wire and cable length, dimensions, and clearance of parts, using precision instruments.
Tests continuity and performance of parts, assemblies, and accessories, using test equipment.
• Ensure the works of installation, commissioning and in the startup (Electrical Switchboard, Breakers, Pumps, Motors, Hydraulic and pneumatic valves), instrumentation ( flow meter, pressure switch, level switch), Strength test, Insulation test, Controller input-output testing.
Keep records and write reports.
Site Survey for the Design of Grounding & Lightning system (Soil resistivity test).
Maintenance, trouble shooting of electrical systems such as Excitation System, Starting Equipment, Protection System, Generator, Transformers, Battery, Battery Chargers, Inverters(UPS), Motors, HV/LV Switchgears, motor driven actuators, DCS, compressor, hydraulic and pneumatic valves.
PLC 300et 400.
PCM 600
SCADA
DCS
PLC
Siemens PLC
Automates Siemens Step 7 …
Automatismes industriels
Installation & Commissioning of all type MW Antenna (0.6m, 1.2m, 1.8m, and 2.4m) .
• Swap, Installation and Integration of 2G, 3G and LTE Technologies and Microwave Transmission
• Installation of BTS, Indoor, Outdoor
• Integration of BTS Sites
• Site Integration manually and by Using WDT Software of Huawei .
• Downloading software, Script, configuring and removing components using LMT for Du/Huawei .
• Antenna cutover and sector addition, new outdoor Site Installation and Commissioning.
• Dismantling of Existing BTS, MW-hope, IDU, ODU, Antennas & Accessories
• VSWR Measurements & Alarm rectification of Existing cell sites
• Self-Assessment of installed site
• Site Documentation & inventory management
• Quality Work and Acceptance Test PAT.
• TRX Addition with New and Existing sites.
• DTRX Segmentation
• Installation of GSM and CDMA Antennas.
• Installation and testing PS (power supply).
• Test KPI
• Upgrading BBU for 3G and LTE.
• Maintenance of alarms NSBT, DDF, ODF, AISG cable, VSWR.URFU V2, URFUd.
• Installation, commissioning RTN 950, RTN 980.
• Supervision of Installation for RTN (900, 910, 950, 980).
• Configuration Experience of RTN Using U 2000 Web LCT.
• Troubleshooting the E1 alarms, services alarms, IDU alarms and cross connection alarms.
• Setting NE Communication Parameters.
• Installation and Alarm configuration of Huawei Power supply
Installation & Commissioning of all type MW Antenna (0.6m, 1.2m, 1.8m, and 2.4m) .
• Swap, Installation and Integration of 2G, 3G and LTE Technologies and Microwave Transmission
• Installation of BTS, Indoor, Outdoor
• Integration of BTS Sites
• Site Integration manually and by Using WDT Software of Huawei .
• Downloading software, Script, configuring and removing components using LMT for Du/Huawei .
• Antenna cutover and sector addition, new outdoor Site Installation and Commissioning.
• Dismantling of Existing BTS, MW-hope, IDU, ODU, Antennas & Accessories
• VSWR Measurements & Alarm rectification of Existing cell sites
• Self-Assessment of installed site
• Site Documentation & inventory management
• Quality Work and Acceptance Test PAT.
• TRX Addition with New and Existing sites.
• DTRX Segmentation
• Installation of GSM and CDMA Antennas.
• Installation and testing PS (power supply).
• Test KPI
• Upgrading BBU for 3G and LTE.
• Maintenance of alarms NSBT, DDF, ODF, AISG cable, VSWR.URFU V2, URFUd.
• Installation, commissioning RTN 950, RTN 980.
• Supervision of Installation for RTN (900, 910, 950, 980).
• Configuration Experience of RTN Using U 2000 Web LCT.
• Troubleshooting the E1 alarms, services alarms, IDU alarms and cross connection alarms.
• Setting NE Communication Parameters.
• Installation and Alarm configuration of Huawei Power supply
5 years