Senior Engineer
NOMAC
Total years of experience :34 years, 0 Months
Position Held Period Field of Work Place of Posting Organization/ Department
Senior Engineer/
Head of Department
February 2009 to date
• Installation, Commissioning and Maintenance of 3X400 MW Thermal Power units with 3X4 Desalination units with SIEMENS, ANSALDO and DOOSAN.
Shuaibah-III near Jeddah Kingdom of Saudi Arabia
• Assigns preventive and corrective maintenance jobs as per the direction of Maintenance Manager. Supervises and co-ordinates activities of maintenance staff. Maintain records, prepare reports and composes correspondence related to work.
• Executes work orders through CMMS (SAP) and co-ordinates with planning engineer for job completion and technical matters.
• To perform technical evaluation of quotations received from purchase department and recommended appropriate chaise.
• To prepare purchase requisitions for spare parts and consumables ensuring budgetary constraints and arrange strategic spares availability to cope up with the maintenance requirements.
• Review and recommend new maintenance procedures and work instructions.
• Supervise, direct and co-ordinate the activities of all personal assigned to his area.
• Ensure Environmental Aspect- Impact and hazard Risk Assessment are carried out, controlled and updated.
• Ensure Legal compliance with respect to their scope of activities.
• Carry out annual performance evaluation of reporting employees.
• Responsible to ensure the compliance to legal requirements, contractual and organizational requirements.
• Provide on-job training to new employees and evaluate their OJT Performance.
• Identification, documentation and control of hazards in assigned work area.
• Reporting of emergencies and incidents and near misses.
• Effective resource utilization.
• Perform other duties as assigned.
7. Incident Investigation Team Leader Course. Based on Root cause Analysis Technics 03 Days Oct, 2011 By MAXTRAIN INTERNATIONAL HSEQ Trainees, Consultant & Risk Management Advisors
PROVEN CAPABILITIES: 1) 80 Days Major Over hauling of 2X210 MW Steam Turbine units (Make
05 Days Dec 2010
A course approved and validated by the Institution Of Safety And Health (IOSH) in association with Energy Industries Training Centre (EiTC)
4. Training for Automation Systems and Drives Technology. SIMATIC S7TIA- Services and Maintenance course 1 (ST-SERV1) 5 Days Nov 2009 Shuaibah-III training centre By: Sitrain, Siemens Limited
5.
In house Training Course on "Integrated Management System" (ISO 9001:2008, ISO 14001:2004 & OHSA 18001:2007
4 Days July 2010
At Jeddah, Conducted by: National Inspection & Technical Testing Co. LTD (FAHSS/TUV) Damam, Saudi Arabia (TUV NORD) Saudi Arabia
6.
Managing safely
NOMAC First Operation And Maintenance Company
Electrical Maintenance Engineer September 2003 to February 2009 • In-charge of 2X210 MW Thermal Power Plant Guddu. Responsible for Maintenance and Management. Thermal Power Station Guddu-Kashmore WAPDA CENTRAL POWER GENERATION COMPMANY (GENCO-II)
DUTIES AS MAINTENANCE ENGINEER:
• Assigns preventive and corrective maintenance jobs as per the direction of Maintenance Manager. Supervises and co-ordinates activities of maintenance staff. Maintain records, prepare reports and composes correspondence related to work.
• Executes work orders through CMMS (SAP) and co-ordinates with planning engineer for job completion and technical matters.
• To perform technical evaluation of quotations received from purchase department and recommended appropriate chaise.
• To prepare purchase requisitions for spare parts and consumables ensuring budgetary constraints and arrange strategic spares availability to cope up with the maintenance requirements.
• Review and recommend new maintenance procedures and work instructions.
• Supervise, direct and co-ordinate the activities of all personal assigned to his area.
• Ensure Environmental Aspect- Impact and hazard Risk Assessment are carried out, controlled and updated.
• Ensure Legal compliance with respect to their scope of activities.
• Carry out annual performance evaluation of reporting employees.
• Responsible to ensure the compliance to legal requirements, contractual and organizational requirements.
• Provide on-job training to new employees and evaluate their OJT Performance.
• Identification, documentation and control of hazards in assigned work area.
• Reporting of emergencies and incidents and near misses.
• Effective resource utilization.
• Perform other duties as assigned.
Electrical Engineer
May, 1992 to Feb, 2003
• Site inspections and technical support to site staff.
• Repair, maintenance and installation of equipment of 2X210 MW Thermal Power Plant.
Thermal Power Station Jamshoro
China) installed at TPS Jamshoro, WAPDA, Pakistan during January, 1999.
• Major Over Hauling and maintenance of 2X210 MW Hydrogen/Water cooled Turbo-Generator Model: QFSN-210-2.
• Over Hauling of 250 MVA, 15.75/242KV Unit Power Transformer it's Testing & commissioning after over haul.
• Over hauling of 25 MVA 15.75/6.6KV unit Auxiliary Transformer it's Testing & commissioning after over haul.
• Over hauling and maintenance of all 6.6KV, 0.4KV Motor's & Switch gears.
• Maintenance and commissioning of 1800AH, 220V DC system Battery Bank.
• Overhauling and maintenance of Excitation System KGT-2E Auto Voltage Regulator.
• Testing & commissioning of Current Transformer's & Potential Transformer's.
2) 75 Days Major Over hauling of 2X210 MW Steam Turbine units (Make China, USSR) installed at TPS Guddu- Kashmore, WAPDA, Pakistan during December, 2004.
• Major Over Hauling and maintenance of 2X210 MW Hydrogen/Water cooled Turbo-Generator Model: QFSN-210-2.
• Over Hauling and maintenance of 3*95 MVA, 220KV/132KV Auto-Transformer & its Air blast circuit breaker.
• Over Hauling of 250 MVA, 15.75/242KV Unit Power Transformer it's Testing & commissioning after over haul
• Over hauling and maintenance of all 6.6KV, 0.4KV Motor's & Switch gears.
• Maintenance and commissioning of 1800AH, 220V DC system Battery Bank.
• Overhauling and maintenance of Excitation System KGT-2E Auto Voltage Regulator.
• Testing & commissioning of Current Transformer's & Potential Transformer's.
3) 05TIMES, 28 days Minor Inspection of 1X400MW Stem Turbine unit (10) and 4 Desalination Plants (Make Siemens-Germany, Ansaldo-Italy & Doosan-Korea) Installed at Shuaibah, Jeddah First IWPP in the Kingdom of Saudi Arabia During February, 2012.
• Inspection and annual preventive maintenance of: • Inspection and testing of Generator after dis-assembling/ assembling as per O&M manuals recommendations.
• Fast-Gen Robotic inspection of stator wedge tightness testing of stator (Rotor inside the stator)
• Gen-Transformer 497MVA.
• Unit Auxiliary Transformer 80/40/40 MVA
• Excitation system (Single Excitation Equipment)
• 13.2/6.6/0.4KV motor and Switch Gear.
• Electro Static Precipitator (ESP) system.
• FGD system
• AREVA MiCOM P series Relays (P122, P141, P225, P521, P922)
• SIPROTEC47UM & SIPROTEC7UT Protective Relays (Siemens)
• Emergency diesel generator 10MVA
• High Speed Bus Transfer System (HSBT)
• Auto Bus Transfer System (ABTS)
DUTIES AS OPERATION ENGINEER:
Improved the efficiency of a running plant and trouble shooting, to suggest modification in operating procedures, to hand over the equipment for maintenance in a safe condition and co-ordinate between various maintenance departments, to plan for annual turn around, to ensure safe and economical startups and shutdowns.
DUTIES AS MAINTENANCE ENGINEER:
• Assigns preventive and corrective maintenance jobs as per the direction of Maintenance Manager. Supervises and co-ordinates activities of maintenance staff. Maintain records, prepare reports and composes correspondence related to work.
• Executes work orders through CMMS (SAP) and co-ordinates with planning engineer for job completion and technical matters.
• To perform technical evaluation of quotations received from purchase department and recommended appropriate chaise.
• To prepare purchase requisitions for spare parts and consumables ensuring budgetary constraints and arrange strategic spares availability to cope up with the maintenance requirements.
• Review and recommend new maintenance procedures and work instructions.
• Supervise, direct and co-ordinate the activities of all personal assigned to his area.
• Ensure Environmental Aspect- Impact and hazard Risk Assessment are carried out, controlled and updated.
• Ensure Legal compliance with respect to their scope of activities.
• Carry out annual performance evaluation of reporting employees.
• Responsible to ensure the compliance to legal requirements, contractual and organizational requirements.
• Provide on-job training to new employees and evaluate their OJT Performance.
• Identification, documentation and control of hazards in assigned work area.
• Reporting of emergencies and incidents and near misses.
• Effective resource utilization.
• Perform other duties as assigned.
WAPDA
CENTRAL POWER GENERATION COMPMANY (GENCO-I)
Operation Engineer
May 1990 to May 1992
• Operation Engineer (2 yrs)
2x210 MW Thermal Units 3, 4
Thermal Power Station Jamshoro
WAPDA
CENTRAL POWER GENERATION COMPMANY (GENCO-I)
Professional Trainings
S. No. Name of Training Duration Training Center
Bachelor degree in Electrical discipline. Year of passing 08.11.1986. Awarded grade-A.
Intermediate (HSC) 1980 B.I.S.E Hyderabad 'C' Second Class.
Secondary School Certificate (SSC) 1978 B.I.S.E Sukkur 'B' Distinction in two subjects.