MELVIN TAJARDON, MAINTENANCE TECHNICIAN, ELCTRICAL

MELVIN TAJARDON

MAINTENANCE TECHNICIAN, ELCTRICAL

FUJAIRAH OIL TERMINAL

Location
United Arab Emirates - Dubai
Education
High school or equivalent, INDUSTRIAL TECHNOLOGY / ELECTRICAL
Experience
14 years, 9 Months

Share My Profile

Block User


Work Experience

Total years of experience :14 years, 9 Months

MAINTENANCE TECHNICIAN, ELCTRICAL at FUJAIRAH OIL TERMINAL
  • United Arab Emirates - Fujairah
  • My current job since October 2015

JOB DESCRIPTION

• Responsible for trouble shoot, repair and maintenance of electrical systems for different type
• Responsible for trouble shoot, repair and maintenance of electrical systems in all Gathering Centers, Booster Station, Field Distribution.
• Prepare spare parts list as per the equipment.
• Maintain all hand Tools & Power Tools.
• Perform other related duties as assigned.

DUTIES AND RESPONSIBILITIES:

Hands on Experience in Oil Gathering Centers and Storage Tanks. Operation and Maintenance of Electrical power system Equipment as per Hazardous Area and Safety Rules and Regulation. Operation and Maintenance of Flame proof, Increased Safety, Non Sparking type of HT Motors and All Ranges 6.6 KV, 3.3 KV and 440 V up to 650 KW in Hazardous area of Zone 1&2 and Variable Frequency Drives. Maintenance, Troubleshooting, Fault Rectification and Calibration of MOV’S. Maintenance of different type of UPS and Battery Banks NiCad and Lead Acid. Fire Alarm& Extinguishing system with Ionization smoke detector, Heat detectors, Manual Break glass units with automatic Extinguishing System.(FM200) Operation, Maintenance and Overhauling of LT & HT Flameproof Vertical and Horizontal AC and DC Motors. Troubleshooting and Fault Rectification of MCC and PCS Panels. Operation, Maintenance in 75 Hp Air Compressors. Operation, Maintenance of all motor Starters. Maintenance of Power Transformer up to 6.6 KV & Control Transformer and its operating Systems. Testing Breakdown Voltage of Transformer oil and Meggering of Transformer. Maintenance all type of Switchgears like MCB, ACB, and VCB Circuit Breakers & Motor Starters like DOL, Star - Delta Starters and Auto Transformer Starters Equipped in Main Switchgears and MCCS. Maintenance of Battery & Battery Charges and AC&DC UPS System. Erection of Panels and Distribution Boards, Laying, Glanding, Jointing and Termination of Cables up to 300 Sq mm. Maintenance Erection, Testing and commissioning of pressure Gauge& Transmitters, Level indicators & Transmitters, pneumatic control valves, Thermocouples and RTD’s. Issue Isolation Certificates and perform LOTO, making sure that everything is safe and smooth before De-isolating system.

MAINTENANCE TECHNICIAN, ELCTRICAL at FUJAIRAH OIL TERMINAL
  • United Arab Emirates - Fujairah
  • My current job since September 2015

Carry out preventive/corrective/breakdown maintenance in all electrical equipment like, 6.6 KV and LV switchgear, 12.5 MVA Transformers, 1.1 MVA Diesel Generators (Stamford), UPS and Battery chargers, Power Distribution Boards. Carry out Preventive maintenance on field equipment like, MOV, Motor Operated Valves, 6.6 KV/650KW Ship Loading Pumps, Fire Water Pumps, Air Compressors and all types of motors available on the field. Preventive Maintenance and operating procedure of Automatic Fire Suppression System (FM 200). Involved on instrumentation and operation jobs like, functional check of level transmitters, MOV communications to CCR, (Digital/Analog input and Ouput) checking level and pressure gauges during operation. Attend breakdown during operations and following all safety procedures and company policy all the time.

ELECTRICAL TECHNICIAN at MCDERMOTT MIDDLE EAST INTERNATIONAL
  • India
  • February 2009 to August 2013

MCDERMOTT MIDDLE EAST INTERNATIONAL
ELECTRICAL TECHNICIAN
FEBRUARY 04, 2009 - UP TO PRESENT
JOB DESCRIPTION
Testing and commissioning as per preferred company standard and CTP (Commissioning Test Procedure) . I am familiar for commissioning of 11kv, 6.6kv and 3.3kv sub stations and switchboards using feeder management relays GE multilin SR 750, Is Limiter for Bus Protection, Testing and commissioning of Generators, LV, HV and VSD switchboards, commissioning of HT & LT motors.Testing and commissioning of power and distribution transformers including pressure testing, BDV test (Break Down Voltage, and open ckt tests, commissioning of LQ system (living Quarters) with associated systems and HVAC system, Primary and Secondary injection testing, UPS system A.C/D.C, Navigation system, HT, LT breakers, Heat Tracing system, all lighting system, Load Shedding thorough PMS, Loop Checking as per as built drawing, Ductor testing and Hi Pot testing.


WORK HISTORY/PROJECTS

Zakum Development Field at ADMA-OPCO
  • United Arab Emirates
  • October 2012 to January 2013

ADMA-OPCO
Zakum Development Field
October 2012 to January 2013
Abu Dhabi, United Arab Emirates


Duties and Responsibilities
Pre Commissioning and Commissioning of Production Compression water injection and Utility platform (PCWU) and Job involves, Commissioning all type of electrical equipment as per commissioning test procedure (CTP) under Permit to work system as per HSE regulations.11kv, 3.3kv & 400v Cubicles (S&I and ABB), relays, transformers, SOLAR TURBINES Generator (10Mw), motors, compressors, Generator 1.5Mw (Caterpillar) . knowledge in electrical drawings and using all type of electrical testing equipments. Reading of electrical drawings and using all types of electrical tools/equipment like secondary injection kit, Primary injection kit, up to 5 KV megger, loop impedance tester, phase rotation tester, hi pot tester, ductor, RCD tester, Multimeter. Having knowledge in transformer differential relay, feeder management relay (SR750), motor management relay (SR469) and HT and LT switch gears ranging 11 KV and 3.3 KV VCB & ACB, Heat Tracing System, Plant Lighting, Navigation Fog Horn and Lantern.
ARAMCO-KARAN

ELECTRICAL TECHNICIAN at Ras Lafan Oil Field Qatar
  • Qatar - Doha
  • April 2011 to September 2012

April 2011 to September 2012
Ras Lafan Oil Field Qatar


Duties and Responsibilities

Performed Commissioning & Functional test with the Following equipment such as Low / Medium voltage Switchgear, Motors, Transformer, Lightings, Panel, starters. Distribution Board, Including Solo run test, Lock out- Tag out Procedure.Preparation of documents and technical specifations.Planning manpower & material arrangementCoordinating with the commissioning department.Performs inspection, testing, troubleshooting and preventive maintenance of group starter panels.Testing and troubleshooting of lighting and small power distribution board and UPS baterry bank.Monitoring day by day site activities and safety precaution at Site Supervising of works.Conduct testing of all Galley equipment before energization.Testing of system and control, power cables and motors including insulation resistance and check that all installation meets the requirement as per the design and specification.Having good knowledge of plant safety rules and regulations.

ELECTRICAL TECHNICIAN at SHELL PEARL GTL
  • United Arab Emirates - Dubai
  • October 2009 to March 2011

SHELL PEARL GTL
October 2009 to March 2011
Mcdermott yard, Dubai, UAE


Duties and Responsibilities
Installation of electrical systems, cable pulling, glanding and termination. precommissioning of electrical systems, no load and load run test of motor pumps, uninterruptible power supply, LV and HV power distribution, breaker functional testing, cable insulation testing. Loop checking, trouble shooting, punch list clearing., It also includes instruments and fire and gas systems, telecom, etc. I worked with the Mcdermott Project Management for the onshore precommissioning. I am in charge of switchgear operation Lock out tag Out Permit to work system. I was also assigned on precommissioning of UPS start up, Battery charging and discharging, JIB Crane operation and trouble shooting, Emergency Generator, Lighting and small power, I am familiar of using electrical test equipment (Insulation tester, multi function meter, vibration meter, clamp meter, phase rotation meter, low resistance ohmmeter, temperature tester and sound meter. i can read and as built engineering drawings.

ELECTRICAL TECHNICIAN at RAS GAS
  • Qatar - Doha
  • February 2009 to October 2009

RAS GAS Project Wellhead10&11 platforms
February 2009 to October 2009
Ras Lafan Qatar

Duties and Responsibilities
Job like cable laying, Glanding, Termination of HT & LT Power and control cables, Power and Control Cable Continuity Checking and Insulation Resistance Testing .Bus bar and H.V. Cable High pot Testing. Measuring the Insulation Resistance of Bus bar and Continuity Test (DUCTOR TEST) on bus bar Joints. Installation of Lighting and Small Power Distribution System, Light Fitting Installation and Illumination Testing. Motors Winding Resistance and Insulation Test, Cable Glanding and Termination. Ridged steel conduit works, Cable tray works and Trunking.

Electrician/technician at Macanaya Electrical Services
  • Philippines
  • July 2007 to February 2009

Macanaya Electrical Services
Abulug, Cagayan, Philippines
July 2007 to February 2009
Electrician/technician


Duties and Responsibilities
Electrical Installations of residential commercial &industrial Buildings, lighting and convenience outlet installations, electric motors, signals and alarms and other types of electrical equipments. Maintenance and trouble shooting.

Education

High school or equivalent, INDUSTRIAL TECHNOLOGY / ELECTRICAL
  • at MARIANO MARCOS STATE UNIVERSITY
  • May 2007

Specialties & Skills

Microsoft Office
DRAWING
GENERATORS
LIGHTING
MAINTENANCE
POWER DISTRIBUTION
PRESSURE TESTING
SWITCHBOARDS
TESTING
microsoft office

Languages

English
Intermediate

Training and Certifications

NATIONAL CERTIFICATION II (Certificate)
Date Attended:
May 2006
Valid Until:
November 2006