Work Experience

Total years of experience :6 years, 0 Months

Project Engineer ( Protection, Testing & Commissioning) at Delta star Power project ltd
  • Saudi Arabia - Riyadh
  • May 2013 to October 2016

. ABB Service Engineer, Riyadh, KSA

Project Detail & Job Responsibility:


 PP4: Riyadh, KSA

Project detail: 13.8 KV Generator Container installation & scheme diagram checking, testing of electrical equipment

 Qassim University: Al qassim

Project detail: REF 610 relay retro fitting and testing. Circuit breaker testing.

 SWCC’s projects:

Clinet: SSEM; location: PS1: Rumah, PS2: Al Nariyah & PS3: Raz Al Khor

o REF 542 relay configuring, testing.
o ACO (ATS) scheme testing and commissioning.
o MOTOR protection, Starter panel.
o Switch gear panel interlocks.
o All electrical equipment CT, PT, CB, E.S, Monitoring devices.
o Cables & Busbar Higpot, Transformer Testing and Commissioning

 SEC S/S: 7012

Project Detail:
o 33 KV Panel installation & testing.
o Pilot Wire protection MBCI, MCRI, MRTP
o O/C E/F protection REF 615
o Transformer Protection RET 543
o BUSBAR Protection MFAC.,
o CT, PT, CB, E.S, cable, auxiliary relays, spaj relay.
o Remote substation s/s 7010, 8010 A&B pilot wire protection testing and end to end sensitivity
o SCADA check upto FMK panel.

 SNC : KAFD, Riyadh

Project Detail: 13.8 KV panel testing., transformer testing., REF 615, RET 615, Transformer protection, Multifunction meter testing., Auto transfer scheme., CT, PT, CB, E.S, cables., Trouble shooting relay and scheme diagram

 Saudi Binladen Group : KAFD, Riyadh

Project detail: Transformer testing and Temperature monitoring device testing

 NOFA : Riyadh

Project detail: RMU testing and Commissiong. REJ 603 relay testing., transformer testing.




 SEC S/S 7909 & S/S 7910: Al Hail, KSA

o S/S 7910 13.8 KV panel., stuck breaker protection and REF 615 relay retro fitting, two new panel installation
o S/S 7909 33 KV panel., bus bar stability testing and electrical equipment testing

 MODA, QASSIM Airport:
Proteject detail:
o Removing Old 4.16 KV panel and Installing ABB unigear panel.
o Protective relays REF 620 and REF 615 relays
o Synchronizing between line and bus
o Busbar stability

 SEC S/S 8807, 8802, 8805, 8804, 8812 QASSIM, KSA (LAST COMPLETED PROJECT)

Project detail:
o 33 kv SWGR panel Installation testing.
o BUBAR protection (REC670, MFAC)
o Distances Protection (REL 670)
o BUS TIE protection (MFAC)
o Autorecloser, CBF protection, SEF, 50/51 (REF615)
o Testing and scheme modification, commissioning
o SCADA wiring and testing upto FMK

Testing And Commissioning Engineer at INEL Power System Pvt Ltd
  • India
  • November 2010 to April 2013

Precommissioning of water sewage plant: Testing and commissioning of LT Circuit Breakers., LT Panels and Motors., 11/0.433 KV transformer

Chettinad cement: 66/33/11 KV switchyard for KPTCL.

Testing and commissioning of switchyard equipment: CT, PT, Power & Distribution transformer, CB, Protection relays and auxiliary relays ., Lighting arresters and isolators., Tan Delta and Capacitance measurement testing

Ramthal water pumping station: Precommissioning and testing of
11/0.433 KV switchyard and control panels for L&T

Panels., 110/6.6, 12 MVA Power Transformer, CT, PT., Isolators and Circuit breakers., C&R Panel scheme check., OLTC and RTCC panel scheme check

NPCIL, KAIGA: Maintenance Testing Of Relays and Circuit Breakers

Annual maintenance Testing of LT Circuit Breakers, Relays, CT and PT

BWSSB: 220/66/11KV Switchyard for KPTCL

Testing and commissioning of 220/66 KV Switchyard in Harohalli:
Testing and commissioning of 66/11 KV Switchyard in T.K.halli

Maintenance Testing Profile:

Maintenance testing of CT, PT, O/C, E/F relays, CDG, CAG, auxiliary relays, energy meters at Petronet MHB Ltd, Mangalore.
Maintenance testing of auxiliary relays, current transformers, energy meters in Graphite India Pvt Ltd, Mysore.
Maintenance testing of protective relays, auxiliary relays, energy meters in BHEL Bangalore.
Maintenance testing of relays, breakers, CT, PT at NPCIL, KAIGA
Testing of Numerical Differential relay GE G30, T60, F60

COMMISSIONING ENGINEER at ABB Service
  • Saudi Arabia
  • to
Service Engineer at Technical Skill
  • Saudi Arabia
  • to

Testing of various type of power Transformers
Transformer differential protection, Restricted EF, Stability & sensitivity testing.
Busbar differential protection, stability and sensitivity testing.
Pilot wire protection, Line differential protection, Motor protection, Current, voltage protection
Current transformer, Potential transformer, Circuit Breaker testing, Cable high voltage test
Familiar with PCM 600, REF 542+, CAP softwares, configuration
Retro fitting of relays, New panels installation, Scheme Modification, Reinforcement projects.
Scheme diagram checking and trouble shooting
Used Testing Kits:

OMICRON CMC 256 Relay test kit, CPC 100, CT Analyzer, Freja 300 relay test kit, Megger ODEN primary injection, MOM contact resistance and ratio kit

Education

Bachelor's degree, Electrical and Electronics Engineering
  • at Arunai Engineering College
  • January 2010

in

Specialties & Skills

Electrical Maintenance
Service Engineering
Project Engineering
Electrical Protection Engineer
Testing & Commissioning Engineer