MOHAMED RISWAN PM, Electrical Maintenance Supervisor

MOHAMED RISWAN PM

Electrical Maintenance Supervisor

Adnoc Offshore

Location
United Arab Emirates - Abu Dhabi
Education
Diploma, Diploma in electrical and electronics engineering
Experience
22 years, 11 Months

Share My Profile

Block User


Work Experience

Total years of experience :22 years, 11 Months

Electrical Maintenance Supervisor at Adnoc Offshore
  • United Arab Emirates - Abu Dhabi
  • My current job since June 2014

Supervising, coordinating and participating in the activities of personnel in the routine electrical maintenance, overhaul, shutdown and breakdown repair of 33KV, 11KV, 6.6KV and 415V distribution network system.
Carried out 33kv Gas insulated switch gear (8DA10) condition monitoring, SF6 gas leak test and dew point measurement with SF6 analyzer.
Maintenance for 33Kv Gas insulated switch gear (8DA10) and troubleshooting through its siprotec relay DIGSI interfacing software for over fluxing, bus/line differential and HV motor differential protection schemes.
Maintenance for 6.6Kv Schneider MC set Vacuum circuit breaker switch gear and troubleshooting through its Sepam 80 relay interfacing software SFT2841.
Maintenance jobs for 415 Volts Siemens sivacon and comeca make LV switch gears and troubleshooting through these relays interfacing soft wares Simocode pro v and gemstart-5 (Gempro) respectively.
Preventive and predictive maintenance for HV/LV motors, Power, Utility Transformers and appropriate switch gears.
Maintain the daily work log books, maintenance check sheets and isolation log books for completed job.
As a Competent electrical person and AEP to Perform High and Low Voltage switching activities in line with company set policies and procedures to ensure plant safe operations. Under standing the Mechanical inter lock keys exchange during isolation and de isolation of transformer upstream and downstream circuit breakers.
Troubleshooting the interlocking schemes between circuit breaker, earth switch and dis-connector switches.
Assisting to reliability engineers for effectively manage the reliability centred maintenance (RCM) to identify current and emerging maintenance and reliability requirements for plant/assets, establish an adequate reliability program to ensure asset optimization.
Monitor the Contractors electrical equipment's pre commissioning activities and ensure these are executed in accordance with the project technical specifications, quality standards and procedures defined in the contracts.
Interact with Operations team as regards any maintenance and troubleshooting requirement in regular operations, start-ups and shut-downs.
Heat tracing system maintenance and troubleshooting works.
Supervise an electrical pre commissioning, commissioning and start-up activities for assigned sub-systems. This includes preparatory activities and coordinating resources.
 Assisting an electrical commissioning team leader to follow closely the commissioning of systems/subsystems assigned in accordance with the commissioning procedures, commissioning and start-up schedule.
Follow-up on VENDORS commissioning scope of work activities such as: SAT, OTP ’s, documents update, Closing of Punch list.
Review the commissioning check sheets and records in advance to carry the commissioning and start-up activities.
Prepare the method of statements for critical jobs, verify electrical procedures and instructions, plus scope of work for contract jobs and service work orders to meet the company work requirements and standards.
To witness and verify assigned electrical system completion activities performed by the construction Contractor including approval of master punch lists.
Working knowledge in Computerized Maintenance Management System (CMMS) such as SAP PM and MM database to track work orders, raise work requests, requesting materials and update work order statuses.
Work under pressure to handle significant electrical problems and tasks which come up simultaneously and or unexpectedly.
Carries out a variety of administrative activities. Includes preparing daily work activities report, proposed work schedule for the following day, weekly report on status of major activities, monthly work order status report, forms for repair or testing of equipment, request for work to be completed by contractors.

Eletrical maintenance specialist at Qatar Petrochemicals company Q.S.C
  • Qatar - Doha
  • November 2012 to May 2014

Supervise all Electrical pre commissioning, commissioning and start-up activities for assigned sub-systems. This includes preparatory activities, coordinating resources.
Follow-up on VENDORS commissioning scope of work activities such as SAT, OTP’s, documents update, Closing of Punch list.
To assist and control the vendor support required for the assigned systems.
Functionality tests and SAT for switch gears, transformers, UPS.
Solo run and MRT for LV/ HV motors and interpret the ITR-C check sheets.
Battery bank load tests to ensure the backup capacity.
Station power transformers (ABB) 2X 60MVA, 33/11 KV and associated vacuum circuit breaker (SCHNEIDER MC SET) preventive maintenance, condition monitoring jobs and cross check of alarm and trip contacts for WTI, OTI, Bucholz relay and Pressure relief devices.
Station auxiliary transformers (AREVA&BEST)2X27.5MVA, 33/6.6 KV, 4X 4725KVA, 6.6KV/690Volts and 2X 2400KVA, 6.6KV/400 Volts and associated vacuum and air circuit breakers preventive & condition monitoring maintenance jobs.
Hyper compressor synchronous motor (Reluctance type) 11kv, 24.5MW, associated soft starter (SCHNEIDER MC SET) Panel and transformer 9600KVA preventive maintenance jobs.
Extruder induction motor 11kv, 3.2MW, associated VFD (ABB ACS 1000) Panel and transformer 3950KVA preventive maintenance jobs.
Primary compressor induction motor 11kv, 5.6MW and associated VFD (ABB ACS800) panel breaker preventive maintenance jobs.
6X10KW motors and associated VFD (LOHER DYNAVERT) panel’s preventive maintenance jobs.

Lead Electrical Maintenance technician at S2 Operation and Maintenance co WLL.
  • United Arab Emirates - Abu Dhabi
  • October 2010 to November 2012

Siemens Made Gas Turbine (SGT 4000F) Driven Generator 4x245 MW and Steam Turbine Driven Generator 2X340 MW and Associated Power Transformer (HYUNDAI 275&395 MVA), auxiliary transformer (HYUNDAI 80&45 MVA), Gas turbine Startup frequency convertor (SFC), Static Excitation equipment's. Two no’s of cooling condensers and condensate extraction pump motors for steam turbines.Six numbers of MSF (Doosan Make Multy stage flushing units) Cross capacity is 100 MIGD.

Station Power transformers HYUNDAI 375 MVA (16.5KV/400KV) and 272 MVA (20KV/400KV) and Auxiliary transformers 75MVA (20KV/11KV) 45MVA (20KV/11KV) preventive and predictive (condition monitoring) maintenance jobs carried out.
Interpret interlocking schemes for circuit breaker, earth switch, dis-connector switches and mechnical key inter locks keys exchange during isolation and de isolation.
Siemens 340 and 250MVA Generators Breakdown maintenance and inspection works carried out.
Online inspection of exciter carbon brush and replace when required.
Generator shaft grounding system maintenance and replace of carbon brushes when required.
400KV GIS substation Maintenance and inspection jobs carried out.
Black start and emergency Diesel generator (3000KVA-11KV, 1250KVA-440V and 300KVA-440V) set and associated Lead acid battery bank (24V) maintenance, inspection, test run and synchronizing works carried out.
Electro chlorination plant electrolysis rectifier transformer (11KV/400V, 800KVA -Dry type) and associated DC Half wave Converter (160 V DC, 2500Amphs) Condition monitoring and Preventive maintenance works carried out.

Senior electrical maintenance technician at Arabian Petrochemicals Co L.L.C.(Petrokemya) Affiliate of Saudi Basic Industries Corporation (SABIC)
  • Saudi Arabia - Jubail
  • June 2006 to September 2010

Experienced in Troubleshooting, Corrective, Preventive, predictive and Breakdown Maintenance of Electrical Equipments in Low and High Density Poly ethylene plants.
Unipol process technology (LDPE/HDPE) and the Capacity of the plant is 800 KTPA.
Experience in Planned Power outage Shutdown and Start up, Modification of control Circuits, Preventive & Corrective Maintenance and Switching Operations.
Microprocessor base Relays, Static Relays, Electro Mechanical Relays (Thermal relay, Attracted Armature Relays, Induction Relays). (MITSUBSHI, MERLINGERIN, Multiline SIEMENS-Siprotec and ABB)
Calibration of Thermal Relays, Functional check up on Motor Protection relays, Transformer Protection Relays, Feeder Protection relays and Checking Trip and alarms Indication on Local control and DCS Panel.
Power and auxiliary transformers Functional Checks such as Winding Temperature Trip Alarms, Oil Temperature Trip& Alarms, Oil level Alarms, Gas Operated Relay Trip and Alarms, Sudden pressure Relay Trip& Alarms.
Medium and Low Voltage induction Motors13.8 KV, 4.16 KV and 480 Volts the Capacities from 11.5 MW to 0.37 KW Troubleshooting, Corrective and Preventive Maintenance as per SOP's with EPTW system.
Preventive, breakdown maintenance and troubleshooting of 13.8KV 11.5 MW hyper compressor synchronous motors and associated DC Exciter panel.
13.8KV 4.3MW Re circulation pump motor and VCB Preventive, breakdown maintenance works carried out.
Maintenance and troubleshooting of Variable Frequency Drive (VFD- ABB ACS550) 480V, 40KW and 55KW.

Electrical Maintenance Technician at PETROLEUM DEVELOPMENT OMAN L.L.C
  • Oman - Muscat
  • October 2003 to June 2006

Oil and gas exploration, production and process facilities such as oil gathering stations, LNG Process trains, pumping stations, water injection manifolds, steam and water injection well heads, Remote manifold stations(RMS) and outdoor switch yards.
Preventive, corrective and breakdown Maintenance of various electrical equipment’s assigned in E&P facilities of PDO.
All type of Maintenance Activities in Oil & Gas Gathering, Gas lifting plants, well heads & Water injection plants.
Maintenance and troubleshooting of 33/6.6KV and 415v ranges distribution substation equipment’s such as GEC Alstom, SIEMENS and TAMCO switchgears.
Gudor UPS 65, 40&25 KVA System and 240V and 24V DC backup Battery and Charger System.
Maintenance and troubleshooting works in 10.5MW Synchronous Motor and associated DC exiter panel such as driven Gas Lift Compressors. (GEC alsthom)Solar Turbine Centaurs-40, Mars-100, GEC Gas Turbine, Rolls-Royce AVON 1535, Ruston Gas Turbine TB-5000, and NuovoPignone Compressors.
11KV Crude oil Booster pump motor (GEC, Loher, ABB) maintenance, condition monitoring works carried out. (2800KW, 5500KW etc., )
6.6KV Crude Oil and water transfer pump motors 6.6 KV (720, 650 and 405 KW) maintenance job carried out.
4.18KV (180KW) and 480 Volts (22, 35, 46 and 60KW) compressor Loop Oil cooler forced draughts fan motors, and it is Variable Frequency Drive panel(Siemens, Allenbradeley, ABB and loher) Maintenance and troubleshooting works carried out.
Oil well Electrical submersible Pump (ESP) motor (2500HP, 6.6KV and 4300HP 11KV), VFD Panel (ABB, Allenbradeley, and Loher makes) and associated transformer 800KVA (33KV/2KV) Maintenance works carried out.
11KV&33KV oil circuit breaker maintenance works carried out.
Participated in 33KV overhead line isolation and providing padlock, danger notice issues, puts circuit main earths for ESP&VFD Maintenance jobs.
shutdown and inspection job for power transformers (ABB, HUNDAI, EMCO and LS) 11/132KV (145, 160, 210 and 230 MVA) associated switch boards and control relay panels Carried out.

Electrical Technician Maintenance at oil and natural gas corporation
  • India - Mumbai
  • June 2001 to August 2003

Maintenance, troubleshooting, control monitoring, testing and inspection of all electrical equipments.

Involved in commissioning, preventive and break down maintenance of 4 X 35 MW, 42 MVA GAS Turbines Generators, rotary excitation system, AVR and associated power transformers 42 MVA 3.3kv/11kv.
Operation & Maintenance of 6.6 KV and 415 V generation and distribution panels vacuum & air circuit breakers (ABB.GE, AEG).
Ensured availability of stand-by Diesel generator 3x1200KVA (Cummins & Caterpillar) for uninterrupted power system.
Carried out of pre- Commissioning and Commissioning of all electrical power system especially on HV 11kv/415v, 6.6Kv/415v, MCC, Transformer, Switchgears, ACB, VCB up to 11kv. DOL and star-delta starter cubicles etc.

Education

Diploma, Diploma in electrical and electronics engineering
  • at mohamed sathak polytechnic college
  • April 2001

Three years engineering diploma in electrical and electronics engineering.

Specialties & Skills

Maintenance
Troubleshooting
Electrical Testing
Microsoft Office
AEP 33KV LEVEL for switching tasks
Maximo (CMMS)
IP and E Ex codes.
Root Cause Analysis (RCA)
Hazardous area classifications
Troubleshooting,testing and maintenance
Thermography
ESD systems and cause & effect chart’s.
Maintenance,commissioning,PTW,JSA,&HA
SAP-PM&MM Modules
Handling Sepam 80 relay interfacing software SFT2841.
Simocode pro v and gemstart-5 relays
electrical maintenance
oil and gas
High voltage
FLNG Commissioning and maintenance

Languages

English
Expert
Hindi
Expert
Arabic
Intermediate

Training and Certifications

Siemens siprotec relay (Training)
Training Institute:
Siemens learning
Gutor UPS maintenance (Training)
Training Institute:
Gutor
Schneider sepam relay 80 series (Training)
Training Institute:
Schneider electric
H2S Awareness (Training)
Training Institute:
safety technical institute
T BOSIET (Training)
Training Institute:
Safety technical institute
yes (Certificate)
Date Attended:
November 2010
Valid Until:
December 2010

Hobbies

  • books reading, playing foot ball and cricket