MOHSIN PERVAIZ, Project Team Lead

MOHSIN PERVAIZ

Project Team Lead

APD

Location
Saudi Arabia - Riyadh
Education
Bachelor's degree, Telecommunication And Information Technology
Experience
13 years, 11 Months

Share My Profile

Block User


Work Experience

Total years of experience :13 years, 11 Months

Project Team Lead at APD
  • Saudi Arabia - Riyadh
  • My current job since September 2015

Central Region WNI Project Controller!
Complete control on Telecom Implementation (Wireless, MW, Fixed) and closure till PO close.
Full communication to HUAWEI IMs, PMs and TDs for implementation plan smooth execution
on daily basis without any problem. (Access, Implementation, Integration, Site verify).
FULL control over ISDP related tasks. (Roll out, Smart QC, PO Acceptance Application, Delivery
Approval and E-surveys etc.)
Doing spot checks and audits at site for team related issues and reminding them for EHS and
Network safety.
Full hands-on E-PATs, and Uploading STC EPAT docs on FSSO STC Portal.
Full knowledge of Surveys (STC & ZAIN).
Have complete hand on Site Surveys project, TSSR and LOSR for STC, 2D and 3D Surveys for
ZAIN.
Completed various Implementation Projects for STC. ZAIN and Mobily.
5G2, 5G3, 5G4, ASPIRATION, WBB FTK (TE+HO), 4G7, LTE700, LTE2100, LTE1800COL, PTMP
links and MW Projects. 4G Enhancement, Zain Sophia project(s), Zain highway project Under
Zain and Mobily L800, FTK Central, L+12 project.
South Region Project Controller!
Handling projects MW Swap, USF10-USF11-LTE1800COL-LTE-A, and FTK.
Sharing Daily Plan with coordination of Customer.
Line up all teams and resolve their all-relatedissues for Smooth work.
Complete follow up from field teams for daily tasks completion.
Make sure for ISDP and EHS tasks as per standards.
Preparing SIR for any new work done like, Civil, CB, BSS and MW.
Submission of SIR to Customer for smooth monitoring.
Complete supervising/Trouble shooting of installation work for links such as
1+0, 1+1 XPIC, 2+0, 2+SD, 4+0, 4+SD, 8+0 etc.
Huawei BTS (Huawei BTS 3900, 3900L, DBS 3900, DBS 5900 etc.)
Huawei MW links RTN310, RTN380, XMCS RTN950, RTN980, B10, and B20,
ATN905 & ATN910.
Have Worked on both Active and Passive Repeaters MW Links

Project Team Lead at LCC Saudi Arabia (KSA)
  • November 2012 to January 2015

Performing Site RF Survey Coordinator Responsibility!
Had served as project team lead in Huawei STC 4G3 Project for South and North
Region in KSA.
Planning and Supervision of more than 500 sites surveys.
Assigning daily survey plan to related coordinators for their teams.
Coordination with field teams regarding any site issue (Access, lock codes etc)
Escalating all issue to client for resolution.
Making Site Info Data (SID) both Offline and Online for using Huawei BTS3900
AND 3900L.
Making SID reports Acceptance from Vendor and Customer as per standards,
All Supervision of site drawings with CAD teams.
Clearing PO’s on regular basis with customer without any delay.
ALU MPR9500 Microwave Link (Implementation & Commissioning):
Complete Installation, Commissioning, SW update and integration of
ALU MPR 9500 MW Link.
Complete supervising of installation work for links such as 1+0, 1+1 XPIC, 2+0,
2+SD.
Supervising MW rack installation activity and make sure it’s according to floor
plan.
Doing complete installation of Core, MPT and PDH Cards as per NE
Configuration provided in TD.
Commissioning of MPR9500 for said configurations as per TD.
Checking for possible interference issues and inform of customer (if any).
Informing to Customer about any ambiguity exists in the provided design of
link.
Doing software up gradation and necessary SW version download process.
Configuring cross connections, OSPF, VLAN and XPIC Settings.
Make link ready for PAT as per standards of customer without any delay.
Configuring the MPR link with VLAN configuration to be connected to the
7705 router.
Doing all documentation and preparing PAT documents for successful PAT.
Power up the MW using fuse panel from rectifier.
Completing all PAT documents and making Site Inspection Report (SIR).
Manage team for defined targets.
Ensure that MW link will be installed according to Link Budget

Team Lead
  • July 2010 to July 2012
BSS & Txn
  • July 2009 to July 2010

Worked for more than 1 year in Central region MULTAN in
Capital Construction Islamabad (CCI) on TELENOR PK Swap Project with following
responsibilities
I have experience of installation of FLEXI EDGE BTS of NOKIA SEIMENS
NETWORKS (NSN) for TELENOR PAKISTAN
I have experienced of both Hot & Cold swap activities.
Complete Installation & Commissioning of NOKIA Flexi Edge BTS.
Patching & testing of transmission traffic cables.
Patching and verification of DELTA alarms using NRMS software.
Dismantling of Ex-Siemens equipment’s, Siemens BTS 240 XL, Siemens
transmission unit SRAL Xd, NEC, Eltek rectifier cabinet
Handover of all site documents to documentation officer.
Coordination with DT Engineer to troubleshoot Low power, Call drop and Edge
issues.
Indoor & Outdoor Alarms Management.
Performing Sweep Test with Site Analyzer (BIRD or ANRITSU)

Education

Bachelor's degree, Telecommunication And Information Technology
  • at AIOU ISB
  • January 2008

Specialties & Skills

NETWORKING
TROUBLESHOOTING
CONTROL
DELIVERY
DOCUMENTATION
MICROSOFT ACCESS

Languages

Arabic
Intermediate
English
Expert
Urdu
Native Speaker
Punjabi
Native Speaker

Training and Certifications

LCC APPRECIATION CERTIFICATE (Certificate)
Date Attended:
April 2014
HUA APPRECIATION CERTIFICATE (Certificate)
Date Attended:
March 2017
SEDER KSA APPRECIATION CERTIFICATE (Certificate)
Date Attended:
February 2020

Hobbies

  • NEWS, CRICKET, READING