Consultant Electrical Engineer
Lloyds EMEA
Total des années d'expérience :18 years, 10 Mois
Currently managing the Al Ain Distribution Company (AADC) Electrical And Water system project.
Responsibilities includes:
Job Safety analysis of all Electrical and water task
Redevelopment of System Safety Rules for Electrical water system
Development of Operating Instruction for Electrical System on all assets:
o Safety documentations(PTW, SFT and LOA)
o Operating earthing
o Overhead lines
o Underground cables
o Electrical Testing
o Connection and Disconnection asset etc.
Development of Standard Operating Procedure in
compliance OSHAD
o LV Live working on LV voltage feeder pillars and
service turrets
o Live LV Work - Protection Control Panels
o Sulphur Hexafluoride gas
o Standby generators
o Substation batteries (Batteries banks)
o Replacement of fuse cut-out of Pole Mounted Transformer
o Access and working hazards at AADC network
o Hot works
o Driving and traffic control
o Lone working
o Lifting activities and Manual handling
o Power tools
o Stacking and Storage
Personal Protective Equipment specification and matrices for electrical and water disciplines task.
Development of Training material on:
o Job Safety Analysis
o Incident and accident investigation
o Electrical Safety
o PPE -Correct use, care and Storage etc.
Lead training programs on safe work procedures and demonstration of best Operational and Maintenance practices as per developed Company procedures and international standards.
Delivered Technical and Safety trainings on following
o SEC Distribution Safety Rules
o Authorization of Operational Distribution staff
o Work Permits (MV PTW, SFT, LOA, LV PTW and
Confined Space Entry Permit)
o Lockout Tag out- Hazardous Energy controls
o Electrical Network Shut down and Switching Procedure
o Hazard Analysis and Risk Assessment
o Use and Care of PPE and First Aid- Basic Life
Support Program
Lead Internal Audits, Gap analysis and Supported
corrective follow up of 5 Star Health and Safety
Management system in all SEC Distribution
departments.
Conducted work site inspections and performed
complete job hazard analysis by following appropriate Engineering and administrative controls.
Investigated Accidents and Near miss incidents and
defined root causes and recommended preventions
Delivered to Supervisors, Foremen and Field staff technical training courses listed below:
A. Equipotential grounding
B. First aid responder
C. High voltage “Permit to work” (PTW).
D. Basic electrical concepts, testing / measuring instruments and their use.
E. Installation and maintenance of all apparatus used in overhead and underground e.g. conductors, cables, transformers, voltage regulators, auto reclosers and steel structured etc.
F. Use, care and replacement of Personnel Protective Equipment (PPE). G. Patrolling of electrical lines, location of faults.
Developed and documented the procedures according to organization requirements listed below. A. Meter reading trainer manual B. Assistant linemen trainer manual
Developed and coordinated all classroom training materials with managers and supervisors.
In Preventive Maintenance Section;
Planned, scheduled and supervised the maintenance work of primary and secondary overhead and
underground distribution system, Transformers, Switch reclosers, Sectionalizers, Capacitor banks and other equipment
Supervised switching operations to carry out Preventive maintenance activities and made
recommendation pertaining to improvement in distribution system
Inspected facilities and reported to correct irregularities and abnormal conditions
Provided assistance to the Emergency maintenance staff in case major break and system damages occurrence
Assisted in the administration of Safety Program and enforcement of Safety policy and practices
In New Service Connection Section;
Planed new service connection of domestic and commercial categories of up to 15 KW Load
Arranged material and supervised the construction of new service connections and augmentation of
existing load
Supervised and assisted in directing various phases of contracted work of new overhead & underground system construction, tree trimming, right of way clearing structure and foundation painting etc.
In Meter Reading Section;
Supervised field tests, inspection, repair, removal and installation of Energy Meters and its equipment
Checked and supervised the preparation of Meters reports and implemented collection of record for billing
Directed and supervised the activity of Disconnection & Reconnection order, Meter Change & Equipment Removal Order as per company standards and procedure
In Testing and Inspection section;
Supervised installation, testing and commissioning of High and Low voltage equipment:
o Circuit breaker, Ring main unit, Auto re-closer, Distribution, Current and Voltage Transformers, Low
voltage distribution pillars and KWH energy meters.
o HV Circuit breaker opening and closing timing test
o HV Circuit breaker Contacts resistance test
o Isolation and Insulation resistance test
o Turn ratio tests
o Phase Sequence and Ground resistance tests
Bachelor degree in Electrical Technology
Associate Engineer in Electrical