Painting Inspector (On Behalf of PT.NeoGenesa International)
Linde
Total years of experience :8 years, 8 Months
Repainting FBST and Cold Box Equipment with Wet Blasting surface preparation method in hence of debris and other contaminants it can be captured.
• Liaise with team Scaffolding and Painting day by day what is to be considered unsafety working manner to safely work on site (working at height and windy location)
• conducting test it has been done (Dry Temp, Wet, Temp. RH, DEw Point, Steel TEmp, Cleanliness, Blotter Test, Roughness/profile/key, Wft, Dft, Conductivity Test / Salt Test, Pull off Test)
• Liasie with Rope Access team to install Logo, Powertools and painting on coldbox due to high risk job 61 meter Height
• Reporting Monthly or weekly to Deputy ops Manager Plant (Painting Report) and have agenda to mitigate the plant such as if any corrosion emerging heavy pitting, anomalies, in connection with the loss pressure of Lar, Lin and Lox FBST
• Supervise manpower to make correct working refer to the specification of the project
- Doing Inspection Test Blasting and Painting Activities ( Fire Extinguisher Line Pipe Facility) material includes : H Beam, U Channels, L-angel and Various Pipe Size.
- Stacking material has done production in proper manner ( prevent bi metallic pathway)
- regularly calibration of DFT and Dew point meter
Jambaran Tiung Biru - Onshrore Processing Facility Blasting And Painting in Talok Workshop Facility
- Doing all activities related Logistic, Commercial, Mock Up test, Production test Painting.
- Engage with RFId System to track Properties of pipe counter part to QA/QC production process ( from Welding, Painting and Load out to Field)
- full load capacity bargaining with local community (Asking to involve in Project)
Application Lining Coating in Gas Separator Vessel using product interline 1064, Patching Method ( Severe area Condition is mandatory to be repaired ) Surface Preparation with Bristle Blaster power tools monti Germany product equivalent to Sa 2 1/2 for further sequence apply hand trowel interline Volume Solid 100 % as thickness requirement 1.200 Microns
Pertagas Project Removal Bitumen as Existing Paint - Inspection Painting Test within Specification Surface Preparation Hand And Power tools Iso 8501 st 2 and St 3 required thickness 2 x 100 Microns Primer (Epoxies Surface Tolerance) and 75 Microns Finish. Pipe Crossing Bridge WJA territory includes; 1. Bitung District (K59, K58, K69, K13) 2. Tegal Gede District (K141, K133, K123, K116, K102, K101, K88, K87) 3. Mundu District (Kali Beji Bridge, Kali Pangkalan Bridge, Kali Cimanuk Bridge) 4. SKG Cilamaya Inspection and Supervise all above area mentioned with different team respectively
Hot Insulation Pre-Fabricated for Small Bore Pipe at Maleo Producer Use MG Wire Blanket with water repellent CUI CAmpaign at OPF Grati conducting Cold and Hot Insulation replacement and Installation of window check on suspicious thin plate
-Inspection test during production Blasting and painting of structure ( walls, beams, columns, roof and stairs ) applied by Rust Bullet / single paint product.
- for static machine shoe factory, application of floor water borne epoxy system using product FLowcrete
Clarifier A Re-Painting
Anoa Platform PFP Construction
Onshore Processing Facility Grati
• Construction of Cold Insulation on various process pipe from chiller as result of condensing from process gas to inline metering pipe. ( Polyurethane Rigid Pipe cover)
• Constuction of Hot Insulation Pipe size 2 and 4 for Gas Engine Generator Compressor / Suction compressor from Wortel and Oyong Well caused decrease of natural gas flow
CP 19 PGN Project, Pipelines 12, 5 Km (Immersed Pipe) length from Otsuka pocari sweat Kejayan Plant to Purwosari Intersection Road. Pipe OD 10.
• Check All activities ( Sa 2 1/2 and roughness not less than 65 microns and apply heat shrinkable Epoxy sleeves /HTLP 80.
• its around 1.400 joint
Repainting Maintenance Campaigns include these equipment :
• Chimney 72 meter Height
• Demin Area
• Clarifier and condensate Tank
• Water Treatment Pond using the product Rust Bullet trademark with single paint system / the revolutionary product
Maleo Booster Train 3 Compressor construction hot insulation on exhaust compressor
PM-CMS Software gives Explanation and data entry of :
• a tree tags model of equipment, component and system
• Libraries of ITR test sheets and allows these to be assigned to components of the Plant
• Linking back of scans in completed Checksheets
• Drag and drop linking of documents from the documents library to the Tags Tree model
• Auto assigning of check sheets for tags based on tag types
• Reports status, progress, work outstanding, anomalies etc
• Punch Lists tracking and management.
• Integrated XL stripper with data mapping for fast importing of Tag Data.
• Integrated bulk planning feature for setting dates for check sheets with built in progress SCurves.
• Prioritises & Orders Systems for Start Up
• Holds set-points, trips, inhibits, spades, overrides
• Construction of Acoustic Insulation in Engine Room and Clinic MOPU (ceiling deck and wall partition) using product Rockwool thickness 25 mm with density 60 kg/m3 covering with glass cloth to comply with COSHH regulations.
• Hot Insulation Construction on Booster Compressor Train 3 on Maleo Producer MOPU (Mobile Offshore Producing unit Using Calcium Silicate with density 120 Kg/m3 and thickness 50 mm. Jacketing SS 304 thk 0.6 m.
• Apply Chartek-7 (Intumescent Epoxy PFP) on fire Wall the function is the worker can easily to evacuate if possible hydrocarbon fire explosion near the well
Painting of Glass Flake type on water intake Pipe OD 56 - 60. for cooling water from sea water to turbine of Coal Fired power plant 2 x 112 MW
Turn Around (TA) Project
• Check during all Activities to relative requirements ( Cleanliness Sa 3 ISO 8501 or BGAS 7079 pt A, Roughness 75 - 115 Microns, Wet film and dry film with requirement thickness 5 - 10 mm. product from Henkel ( Brushable ceramic Grey) resistance up to 1000 deg Celcius (Heat Exchanger Vessel)
Chevron Sphere leg Propane A And Buthane B Tank PFP Refurbishment Chartek-1709
Tunu Phase 12&13 A Development Project for Total Final Elf Indonesie
- Check all Activities during application, various range thicknesses from 2.55 mm to 24.5 mm ( 8 Vent LIne, Wall Cabin (Electrical room), Skid KO Drum Vessel, 12 Producing line from Well to GTS) Chartek-7 Product
• Tunu Phase 11 for Total Indonesie
• Inspection Test
• Various Specification H30, H60, H90, H120 JF 120
• Conduct blotter test if any visible oil and water as per ASTM D 4285
• conduct test of Cleanliness and Roughness of Profile, key or amplitude of Blasting result referring to Specification
• Monitoring and measurement of Ambient Temperature (Dry Temp, Wet temperature, Dew Point Temp and Relative humidity) and Steel Temp before application of Painting
• Complies to Painting System Client Total Elf Indonesie - GS Cor 350
• Check Wet film thickness at which applying Paint and Dry FIlm thickness as a final result as per specification
• check any defect of painting and conduct repair
• monitor and reporting to Deputy Manager if any sequences of the jobs do not conformance as per spesification
• conduct holiday test in Mud tank if any pinholes detected and do repair / stripe coat
• reporting daily, weekly and Monthly Report
I have conduct in supervise and inspection of all aspect are required by client to achieve specification which has been stated.
my last experience in past 15 years are Passive Fire Proofing, Insulation, and Blasting Painting
• Secured additional projects for Passive Fire Proofing (PFP) and other prospective coating inspections.
• Conducted meticulously inspected fireproofing coatings at WHP Oyong
• Performed comprehensive fireproofing coating inspections for Santos Sampang Pty Ltd
• Maintained stringent quality control standards for fireproofing application processes.
Apply PFP (intumescent Epoxy System) on ESD (Emergency Shutdown) Valve at Pig receiver line through gas Producing from Oyong And Maleo Field
• Scheduling and Handling material with proper logistics as required from Manufacturer PFP (Intumescent Epoxy) eg Chartek-7.
• meet the clients needs Santos Ltd in order with the specification H120 JF 60
• Conduct Mock up test it has been witnessed Technical Paint Manufacturer - International Paint, Labroy Shipment Ltd - FSO Fabricator, Santos Ltd - Client