QAMAR  ABBAS, Electrical Testing &Commissioning Engineer

QAMAR ABBAS

Electrical Testing &Commissioning Engineer

ALFNANAR TESTING & COMMISSIONING

Location
Saudi Arabia - Medina
Education
Bachelor's degree, Electrical Engineering
Experience
11 years, 9 Months

Share My Profile

Block User


Work Experience

Total years of experience :11 years, 9 Months

Electrical Testing &Commissioning Engineer at ALFNANAR TESTING & COMMISSIONING
  • Saudi Arabia
  • My current job since August 2015

PROJECTS:
 380KV/115KV/13.8kv AL- Juaymah substation
 380/110/13.8Kv Saline Water Conversion Plant and Power Plant in Jeddah city
 132/13.8KV Olayia-2 S/S 8204 Substation Riyadh
 380/132/13.8Kv Riyadh Metro (9053)
 380/132/13.8Kv Riyadh Metro (9054)
 Jeddah South Thermal Power Plant 635mw Commissioning Of BOP AREA LV MV SWGR.
 132/13.8Kv Khaldiya-2 S/S Nijran.
 132/13.8Kv MC-2 ABHA S/S.
 380/110/13.8Kv Yanbu City S/S.
 380/110/13.8Kv Khaldiya S/S for Saline Water Conversion Plant and Power Plant in Jeddah city
 380/110/33/13.8 KV MAHAD AL -DHAHAB S/S
 380 KV S/S (9033) Fixed Series Compensation (Reinforcement of Central West Power Transfer Capability)
 Testing & Commissioning from 380kV to 33 KV Switchgear, 66KV to 380 KV Switchyard & 132KV, 110kv, 380 KV GIS (Gas Insulation Substation).
 Testing of CT, P.T, CVT, Power Transformers, shunt reactors, grounding transformers, Neutral Ear thing Resistors, Dis-connectors, UG cables, Bus Bar, HT&LT Motors, and Transformer (150KVA-500 MVA) testing with Differential protection, REF protection etc.
 Ability to operate various testing tools and equipment including Megger, Digital Multi-meter, Multi-Amps Relay Tester, primary and secondary injection set, etc.
 Practical Working exposure with advance relays Configuration, Setting, SAS interface MICOM, SIEMENS, ABB, SEL, ZIV, and GE relays,
 Fault Analysis of Fault on T.L (all Brand of relays). Preparation of Fault report as per SEC standard.
 Live inspection of Transformer, Bus bar, GIS, FSC(Fixed series compensation to control line impedance),
 Arrange Shutdown with CRCC, Isolate Working area Issue Safety Permits (LOA, STW, PEA, and IER) to contactor.
 Inspection of Control & Relay Panels, preparation of Test Report and cable schedule for sub-station. Panel re-scheming, testing of 13.8kv equipment, Interlocking etc.
 Testing protocols management according to client standards SEC, NATIONAL GRID
 Familiar with Key Diagrams, Control and Protection Switchyard and Switchgear Electrical equipment’s.
Logic Block Diagram, Cable Schedule, Single Line Diagram, Schematic Drawing, Wiring Diagram, Panel Arrangement for control/Protection panels, Local Control Cubicle and Switchgear.
 CT/VT calculation, AC/DC loading and cable sizing.
 Work on protection of Electrical Power system like Line protection scheme, Bus Bar protection scheme, Transformer protection scheme, Pole Discrepancy Scheme, TEE Protection Scheme, ACDB Scheme, DCDB Scheme, Current transformer (CT), Voltage transformer (VT), Isolators, Energy Meters, Relays, Switchgear room, and control circuits.

Electrical Engineer at NIAGARA PROCESSING MILL pvt, Ltd
  • Pakistan - Faisalabad
  • September 2014 to August 2015

connectors, UG cables, Bus Bar, HT&LT Motors, and Transformer
* Troubleshooting, Maintenance all type of Switchgears ACB, OCB and VCB Circuit Breakers &
Maintenance of Battery & Battery Charges and AC&DC UPS System.
* Erection of Panels and Distribution Boards, Jointing and Termination of Cables
* Maintenance Erection, Testing and commissioning of pressure Gauge& Transmitters, Level
indicators & Transmitters, Electro- pneumatic positioners, pneumatic control valves,
Thermocouples, RTD and indicators
* Testing & Commissioning of Switchgear, Switchyard.
* Ability to operate various testing tools and equipment including Megger, Digital Multi-meter, Multi-
Amps Relay Tester, primary and secondary injection set, etc.
* Practical Working exposure to PLC SIEMENS, MITSUBITI

Electrical Engineer at Sitara Chemical Industry (Grid Station, Power Generation).
  • Pakistan - Faisalabad
  • August 2013 to September 2014

 I have working on CTs, PTs, Cable jointing(kitting), Trouble Shooting of 11kv vacuum CB &132KV SF6 CB And & all types of protection & measuring instrument.
 There are 8 Gas Engines of Jenbacher &2 Gas Engines of DEUTZ
 Each Jenbacher engine has 3mw capacity & each DEUTZ engine has 8mw capacity.
 In Sitara Chemical Industrial chemical reactions are controlled by are controlled by DCS System, manually and combine system.
 Ear thing/Grounding Installation in 132kV grid Operation and Maintenance of Flame proof, Increased Safety, Pressurized type of HT Motors and All Ranges 6.6 KV, 3.3 KV and 440 V up to 1250 KW in Hazardous area of Zone 1&2 and Variable Frequency Drives.
 Maintenance of different type of UPS and Battery Banks NiCad and Lead Acid.
 Operation, Maintenance and Overhauling of LT & HT Flameproof Vertical and Horizontal AC and DC Motors.
 Troubleshooting and Fault Rectification of MCC and PCC Panels.
 Operation, Maintenance in C/P 7.5 Hp Air Compressors.

Trainee Engineer at National Transmission and Despatch Company 220kv Grid Station Nishatabad
  • Pakistan
  • September 2012 to August 2013

* Maintenance Erection, Testing and commissioning of pressure Gauge& Transmitters, Level indicators &
Transmitters, Electro- pneumatic positioners, pneumatic control valves, Thermocouples, RTD and indicators.
* Sitara Chemical Industry (Grid Station, Power Generation). (1 Year operation Aug2013 to Sep2014)
* I have working on CTs, PTs, Cable jointing(kitting), Trouble Shooting of 11kv vacuum CB &132KV SF6
CB And & all types of protection & measuring instrument.
* There are 8 Gas Engines of Jenbacher &2 Gas Engines of DEUTZ
* Each Jenbacher engine has 3mw capacity & each DEUTZ engine has 8mw capacity.
* In Sitara Chemical Industrial chemical reactions are controlled by are controlled by DCS System, manually
and combine system.
* Ear thing/Grounding Installation in 132kV grid Operation and Maintenance of Flame proof, Increased
Safety, Pressurized type of HT Motors and All Ranges 6.6 KV, 3.3 KV and 440 V up to 1250 KW in
Hazardous area of Zone 1&2 and Variable Frequency Drives.

Education

Bachelor's degree, Electrical Engineering
  • at 2013 University of Engineering &Technology
  • August 2013

1st position holder in University

Diploma, Electrical and Systems Engineering
  • at FPI PBTE LAHORE
  • August 2009

Specialties & Skills

oil gas
Electrical Safety
PowerPlant
Testing
Commissioning
CABLEADO
CONVERSION
CUSTOMER RELATIONS
ENGINEERING
GRAPHIC DESIGN
HEWLETT PACKARD

Languages

English
Expert
Urdu
Expert