Syed waqqas Ali shah, Electrical Foreman

Syed waqqas Ali shah

Electrical Foreman

Dortmund & Hubbard L.L.C

Lieu
Émirats Arabes Unis - Dubaï
Éducation
Diplôme, Electronics
Expérience
15 years, 3 Mois

Partager Mon CV

Empêcher usager


Expériences professionnelles

Total des années d'expérience :15 years, 3 Mois

Electrical Foreman à Dortmund & Hubbard L.L.C
  • Émirats Arabes Unis - Dubaï
  • Je travaille ici depuis juin 2015

• Working on Scania (DC 12, DC13, DC16), Himoinsa(CEM 6, CEM 7, CMD 2),
Cummins (QSK 23, KTA 30, KTA 50) Kirloskar Gensets as well as Liehberr Cranes.
• Installation and Synchronization via (Woodward EasyGen 2000 series and 3000 series)
(DSE 8610, 7510, 5510)(Power command PCC 3100, PCC 3200)(COMAP AMF 25)
• Telemetries: Remotely Control and Monitoring of Fleets(Gensets, Cranes, Vehicles)
by using (Atrack AT5, AY5) (Comap Green Guard, Inteli Log)
• Troubleshooting Training/ Supervision Schematics/ Wire Diagrams
• Installation /Electrical Installations/ Maintenance
• Engine component/ Overhaul Diesel Engine Mechanics
• Safety/ HAZMAT/Synchronizing and Paralleling /Electronic Repair/ PLC
• Woodward /Himoinsa/Power command/DSE/COMAP/DATACOM
• ECM, Governor & Speed control units (Perkins, CAT, Himoinsa, Scania,
Cummins, Volvo, MTU, Kirloskar)

Electrical Supervisor à AL MAJD POWER FZE
  • Émirats Arabes Unis - Ras al-Khaimah
  • avril 2013 à mai 2015

• Attended training programs and learnt on-the-job to gain the proficiencies on existing
Product lines.
• Preparing the list of material required for upcoming projects
• Cost estimation and comparison between suppliers to get the best price.
•Make electrical and mechanical wiring modifications to diesel control circuits.
• Performed load testing on units to identify possible problems and prevent wet stacking.
• Performed preventive and corrective maintenance on Automatic Transfer Switches (ATS)
And Annunciator panels.
• Troubleshot and corrected defects of entire generator set systems, including the diesel
engine, generator, engine governor, generator and engine control gear and electrical
Power switchgear.
• Serviced, maintained and installed generators ranging from 5kw-2000kw.
• Operated all standard service tools plus electrical testing equipment.
• Served on rapid response to emergency calls to business and residential standby units.
• Worked with all AC voltages up to 11K volts, 3 phase and possessed a competent working
Knowledge of ISO standards.
• Programmed, calibrated, and tested generators and automatic transfer
Switches.
• Calibrated over and under voltage settings to meet customer expectations.
• Developed generator maintenance program to satisfy all warranty specifications.

ELECTRICAL TECHNICIAN à precision industries
  • Émirats Arabes Unis - Dubaï
  • avril 2012 à avril 2013

Click to edit position description• Worked On Perkins, Caterpillar, Hino, Cummins, Lister Petter, Volvo Diesel Gen-sets
• I Can Install and Repair AVR.
• Installation Of Electrical Switchgears, Relays, Circuit Breakers, Magnetic Contactors,
Potential Transformers, Current Transformers And Timers According To Diagrams.
.• Installation Of AMF And ATS Panels And Load Testing Of Diesel Gen-sets And Quality
Check.
• Operation And Control Of DCS(Distribution Control System) And RTU (Remote Terminal
Unit)
• Performed accurate failure analysis and troubleshooting using sophisticated electronic
Diagnostic tools.

Electrical supervisor à Trade line international power.
  • Pakistan - Lahore
  • août 2008 à août 2011

Click to edit position description• Safely Operating Of Gen-sets And Troubleshoot All Problems During Operation
And Maintain The Working Record Of Gen-sets.
• Installing And Look after Of Temperature Sensors, Humidity Sensors,
• Pressure Sensors
• Operate, Install, Troubleshoot And Maintenance All Kind Of Single & 3-Ph
Synchronous Motors As Well As Dc Motors And Inverter Circuits.
• Overhauling And Routine Maintenance Of Engines
• Test batteries, fuel coolant, and oil; ship oil samples for analysis.
• Conduct automatic and manual transfer tests of simulated power outages to ensure
Generators are functioning properly.

Éducation

Diplôme, Electronics
  • à Hira polytechnical institute of technology
  • juin 2008

I passed high school education with 1st division. Then,passed my D.A.E in A-1 grade.

Specialties & Skills

Maintenance Services
Electrical
Electrical Maintenance
Maintenance Engineering
Generators
Circuit designing
Quality Assurance
generator specialist
electrical
Commissioning
PLC Programming
Troubleshooting

Langues

Anglais
Expert
Arabe
Moyen
Hindi
Expert
Urdu
Langue Maternelle

Formation et Diplômes

EST (Certificat)
Date de la formation:
June 2012
Valide jusqu'à:
July 2012