Senior Electrical Maintenance and installation Engineer
Ridgewood for Water Desalination
Total years of experience :8 years, 7 Months
* I participated in many projects at Hurghada & Sharm el‐Sheikh and North Coast Area (Beach Albatros PX unit - Sunny lakes unit ‐ Sentito unit ‐ Oriental unit ‐ Swan Lake 1st and 2nd PX unit - Haceinda PX unit)
* I troubleshooted many VFD and PLC faults and Solved many problems related to old plc output modules by replacing the output with other way without affecting the control of the unit
* I installed and programmed and operated 4 VFD models ( Schneider - Vacon - ABB - Aqua Drive)
* I installed relay logic circuit instead of defected PLC with all protection of RO unit ( low pressure - high pressure - high conductivity)
* I installed PID control for Schneider ATV 61 and controlled the RPM of the motor so the pressure in the water pipe and protected the pipe from breakage due to high pressure in the case of low water drag.
* I installed pressure sensors and flowmeters to protect RO unit equipments like feed pump & high pressure pump and PX Also * I installed conductivity sensor to monitor and control product water salinity
* I implemented 3 types of motor control panels ( DOL ‐ Star/Delta ‐ VFD )
* I implemented PLC panels ( Modicon M340 )
* I troubleshooted many malfunctions turbocharger and PX units
* I participated in many projects at Hurghada Area (Giftun unit ‐ Marlin inn unit ‐ SIDC 1st and 2nd unit)
Bachelor's degree in Electrical Power and Machines with a grade very good with honor from faculty of engineering, Mansoura University.