mechanical engineer qc
Arail construction and industrial co
Total years of experience :9 years, 8 Months
Meeting with clients to discuss their technical and engineering needs.
• Controls and Maintain QA/QC related documents and preparation of QA/QC monthly Report.
• Co‐ordination with Electrical, Civil, Architectural Engineers before execution of other works.
• Conducts various test as necessary in accordance to the approved construction inspection test plan ITP’s.
• Co‐ordinate with clients and construction engineers.
• Identifying the material as per the standard drawings and specification.
• Witnessing & inspection of the installation of Chiller, AHU, FCU, DX Unit etc.
• Monitoring/ Surveillance inspection for storage, stacking and handling of fittings and consumables including
verification of temperature conditions.
• Inspection for packaging/loading for transportation to site for installation.
• Reviewing and Closing NCR of materials prior to assembly for scratches, damages, cracks,
delamination, crushing, weathering. Witnessing the assembly/ joining of PVC Pipes.
• Verifying thrust block installation at every change in direction of nonmetallic piping.
• Verify and ensure the calibration of instruments for Hydrostatic testing.
• Queries, Construction work package, Method Statements, Checklist, Inspection and Test Plans..
• Reviewing the final package of Hydro Test, approving & releasing for Hydro Test
• Conducting site visits and researching technical processes.
• Analysis and assessment of technical issues.
• Researching, planning, and executing advanced technical solutions
• Preparation of submittals Material approval, Shop Drawing and etc.
• In charge for building inspection and overall installation of HVAC Equipment's (e.g. Air Handling Units, Air
Cooled Air Conditioning Units, Air Cooled Water Chillers, Fans, Exhaust fans, Fan Coil Units, etc.) Ducts /
Chilled water Pipes & Fire water Pipes / Condensate Drainage System.
• Maintain accurate and calibrated inspection tools and equipment for consistent measurements of operation of the
inspection and testing system.
• Inspection of Portable Water Pipe, Fire Water Pipe, Structural, Equipment & Insulation.
• Follow of ASME, ASHRAE & SMACNA Standards.
• Inspection of Plumbing Underground, & Aboveground piping and in process.
• Review the Test packs of piping and witnessing for hydro test
☑️Air Distribution System by Velocity Reduction Method, Equal Friction Method and Static Regain Method following SMACNA Standard.
☑️ESP Calculation for Fans & Blowers.
☑️Toilet & Kitchen Ventilation system Designing.
☑️Staircase pressurization system Designing.
☑️Head Loss calculation for Primary & Secondary pump system.
☑️Design of Expansion tank sizing.
☑️Selection of Chiller, AHU’S, FCU’S, FAN’S, Exhaust Fan, Blower, Window AC, Cooling Tower, Desert Cooler and other Equipment’s.
☑️Installation and Start-Up Trane Chiller, York Chiller (Water-Cooled Condensation type), (1000*6) tons capacity, AHU, FAHU, FCU, HVAC Control Instrument, Control panel, DDC & Loop test for Commissioning, Exhaust Fan, Supply Air Fan Preventive Maintenance, Servicing & troubleshooting etc.
☑️Mcquay water cooled Centrifugal Chiller, (2500*8) tons capacity.
☑️Daikin water cooled Centrifugal Chiller, 2500 tons capacity. York Air Handling Unit 9381 CFM. Capacity.
☑️Mcquay Air Handling Unit 6194 CFM Capacity.
☑️AHU, FAHU, FCU, Package Unit, Duct able Split Unit, Mini Split Unit, Freezer, EF, SAF, Bleed Fan, Pressurization Fan and HVAC control Systems handling.
• Preventive Maintenance, Servicing and Troubleshooting etc.
☑️Extensive knowledge of plumbing (water supply system, drainage system)along with special leak detection system.
☑️Reject or accept the materials in accordance with the specifications.
☑️Apply method statement / checklist at site and generate targeted work order closing.
☑️Stabilized the Maintenance procedure, Achieved 99% PPM & CM completion rate. Improved client satisfaction and team Participation. Improved System & work standards.
☑️Planning and execution of Operation and Preventive maintenance of Chiller Daikin (water cooled 15X 5TR), Trane (Air cooled 4X 270TR) and McQuay (Air cooled 12X 250TR) chiller, Package unit(150X 11TR), FCU (1500X 5TR), AHU (600X 36000CFM), Variable Air Volume units, split Air conditioning and associated pumps and cooling tower.
complete
Client : Mayfair, India Description: Hotel Project (6 floor Building), Calculation of duct sizing by using McQuay software, Air conditioning has been done with 1, 00,000 sft. Air distribution through no of AHU’s, FCU’s and Cassitte unit & 6 chiller cooling with 95TR each.