Total des années d'expérience: 14 Années, 5 Mois
décembre 2021
A À présent
Operation & Maintenance / Planning Engineer
à Bestway Cement
Lieu :
Pakistan - Haripur
Operation & Maintenance EngineerEdit
Harbin Electric International Co LTd, Jhang
Aug 2021 - Present (2 Months)
1. Pre Commissioning & Commissioning of Fuel gas station. 2. Testing of Switch yard primary equipment (CT, CVT, CB, DS, Surge Arrester & Busbar. 3. Testing of Protection relays ( Distance, over current earth fault, Line differential, Transformer protection, Generator protection, Stub protection, Low impedance bus bar protection & breaker failure. 4. Scheme verification of 220 KV bays one & half scheme. 5. Local & remote operation & interlock check.
Harbin Electric International Co LTd, Jhang
Aug 2021 - Present (2 Months)
1. Pre Commissioning & Commissioning of Fuel gas station. 2. Testing of Switch yard primary equipment (CT, CVT, CB, DS, Surge Arrester & Busbar. 3. Testing of Protection relays ( Distance, over current earth fault, Line differential, Transformer protection, Generator protection, Stub protection, Low impedance bus bar protection & breaker failure. 4. Scheme verification of 220 KV bays one & half scheme. 5. Local & remote operation & interlock check.
janvier 2021
A décembre 2021
Lead commissioning Electrical / Protection Engineer
Jai trouvé cet emploi à travers Bayt.com
à Albario Engineering Pvt Ltd (132/220KV Mangla Switchyard Refurbishment project)
Lieu :
Pakistan - Mangla
• Preparing detail shutdown plan as per NPCC & Wapda instruction.
• Commissioning of 132/220KV bay one and half breaker scheme.
• Commissioning of AC/DC system including battery bank.
• Preparing secondary integration drawing for shifting old scheme to new scheme.
• Preparing testing protocol as per contract requirement.
• Configuration, testing & commissioning of protection relays.
• Commissioning of 132/220KV bay one and half breaker scheme.
• Commissioning of AC/DC system including battery bank.
• Preparing secondary integration drawing for shifting old scheme to new scheme.
• Preparing testing protocol as per contract requirement.
• Configuration, testing & commissioning of protection relays.
janvier 2018
A décembre 2020
Lead Commissioning & Design/Protection Engineer
à Lineman Pvt Ltd
Lieu :
Pakistan - Lahore
• Perform AC/DC load flow analysis, Optimal power flow, Unbalance power flow, short circuit analysis, relays coordination, Arc flash analysis, Optimal capacitor placement, grounding grid system, motor acceleration, Harmonic study, DG system study, Renewable energy system (Solar & Wind) Study & transient study on ETAP12.6, ETAP18 & ETAP19.
• Perform service tasks like Installation & commissioning, trouble shooting & routine
maintenance independently.
• Contribute to customer satisfaction by executing service work according to customer order and expectation. Maintain a good relationship with customers. Identify new sales opportunity and contribute internally. Submit site visit report for invoice generation immediately after visit.
• Prepare all documents and reports to be signed by the customer representative. Report work done in a timely manner and follow up when needed.
• Handling the customer for non-confirmation reports / pending item list.
• Maintaining the documentation (red mark drawings, as delivered / as built, software back up) timely.
• Supervising safety regulations on-site as per OHS safety instruction & policy. Ensuring coordination with H&S responsible person on site. Reporting unsafe practices and incidents.
• Perform service tasks like Installation & commissioning, trouble shooting & routine
maintenance independently.
• Contribute to customer satisfaction by executing service work according to customer order and expectation. Maintain a good relationship with customers. Identify new sales opportunity and contribute internally. Submit site visit report for invoice generation immediately after visit.
• Prepare all documents and reports to be signed by the customer representative. Report work done in a timely manner and follow up when needed.
• Handling the customer for non-confirmation reports / pending item list.
• Maintaining the documentation (red mark drawings, as delivered / as built, software back up) timely.
• Supervising safety regulations on-site as per OHS safety instruction & policy. Ensuring coordination with H&S responsible person on site. Reporting unsafe practices and incidents.
novembre 2012
A août 2017
Field Services Engineer
à Arab Technical Services Est.
Lieu :
Arabie Saoudite - Jeddah
• Perform service tasks like Installation & commissioning, trouble shooting & routine maintenance independently.
• Contribute to customer satisfaction by executing service work according to customer order and expectation. Maintain a good relationship with customers. Identify new sales opportunity and contribute internally. Submit site visit report for invoice generation immediately after visit
• Prepare all documents and reports to be signed by the customer representative. Report work done in a timely manner and follow up when needed.
• Testing & commissioning of ELK-04 ABB GIS (132KV), ZX2 ABB GIS (34.5 KV), ZS1 ABB AIS (4.16 KV), Power /Vac Metal clad GE (13.8 KV), AKD-20 low voltage GE (480V), Pix metal clad Schneider Electric (13.8KV), blokset Schneider Electric (480V), Okken schneider electric (480V), UNIGEAR ZS1 ABB (13.8KV) switchgear.
• Testing & commissioning of Limitamp GE (4.16 KV), Evoloution series 900 GE (480V), MSN ABB (480V) MCC.
• Testing of CT, VT, Circuit breaker, contactor, SF6, Bus bar, interlock & functional test.
• Primary Injection for 13.8 KV, 4.16 KV & 480V Switchgear.
• Perfrom stability test for 15/30 MVA three winding HHI transformer.
• Perform stability test for 132 KV line with 145 MVA transformer.
• Testing & commissioning Hyundia power transformer 80 MVA & 60 MVA.
• Testing & commissioning of RTCC (Remote tape changer control) for Hyundia transformer.
• Commissioning of Induction (8 MW) & synchornes motor (20 MW) with GE supervisor.
• Commissioning of Hermetic Pump & WEG motors.
• Perform communicaiton and function test with DCS through profibus SPA ZC302
• PSA/PMS & SCADA testing & commissioning.
• Testing & Configuration of below protection Relays.
1. Feeder Protection Relays: SEL751, SEL451, REF542 Plus, REF541, REF615, REF630, REC 670, Micom141 & VMP255.
2. Motor Protetion Relays: SEL710, REF542 Plus, REM543, REM615, REM620, Schneider LTMR & Micom241.
3. Transformer Protection Relays: SEL787, SEL487E, RET620 & RET630.
4. Line Protection Relays : SEL411L, Micom543, RED615 & RED670.
5. Bus Bar differentional Relays: SEL587Z.
PROJECTS IN SAUDI ARABIA
WA'AD AL-SHAMAL Phosphoric Acid Plant (Turaif, Saudi Araiba). (March 2016 to August 2017).
Position : Electrical Protection & Commissioning Engineer.
Client : MA'ADEN, ( HANWHA & HQC) Through ABB MV Services.
Inlet Gas Treatment Project NGL (Shaybah, Saudi Arabia). (April 2013 to March 2016).
Position : Electrical Protection & Commissioning Engineer.
Client : Saudi Aramco & Samsung Engineering, Through Alfanar Factor..
115/13.8 KV GIS Al-Fakhriyah Substation (Dammam, Saudi Arabia). (Nov 2012 to March 2013).
Position: Testing & Commissioning engineer.
Client: Saudi Electric, Through ABB MV Services.
• Contribute to customer satisfaction by executing service work according to customer order and expectation. Maintain a good relationship with customers. Identify new sales opportunity and contribute internally. Submit site visit report for invoice generation immediately after visit
• Prepare all documents and reports to be signed by the customer representative. Report work done in a timely manner and follow up when needed.
• Testing & commissioning of ELK-04 ABB GIS (132KV), ZX2 ABB GIS (34.5 KV), ZS1 ABB AIS (4.16 KV), Power /Vac Metal clad GE (13.8 KV), AKD-20 low voltage GE (480V), Pix metal clad Schneider Electric (13.8KV), blokset Schneider Electric (480V), Okken schneider electric (480V), UNIGEAR ZS1 ABB (13.8KV) switchgear.
• Testing & commissioning of Limitamp GE (4.16 KV), Evoloution series 900 GE (480V), MSN ABB (480V) MCC.
• Testing of CT, VT, Circuit breaker, contactor, SF6, Bus bar, interlock & functional test.
• Primary Injection for 13.8 KV, 4.16 KV & 480V Switchgear.
• Perfrom stability test for 15/30 MVA three winding HHI transformer.
• Perform stability test for 132 KV line with 145 MVA transformer.
• Testing & commissioning Hyundia power transformer 80 MVA & 60 MVA.
• Testing & commissioning of RTCC (Remote tape changer control) for Hyundia transformer.
• Commissioning of Induction (8 MW) & synchornes motor (20 MW) with GE supervisor.
• Commissioning of Hermetic Pump & WEG motors.
• Perform communicaiton and function test with DCS through profibus SPA ZC302
• PSA/PMS & SCADA testing & commissioning.
• Testing & Configuration of below protection Relays.
1. Feeder Protection Relays: SEL751, SEL451, REF542 Plus, REF541, REF615, REF630, REC 670, Micom141 & VMP255.
2. Motor Protetion Relays: SEL710, REF542 Plus, REM543, REM615, REM620, Schneider LTMR & Micom241.
3. Transformer Protection Relays: SEL787, SEL487E, RET620 & RET630.
4. Line Protection Relays : SEL411L, Micom543, RED615 & RED670.
5. Bus Bar differentional Relays: SEL587Z.
PROJECTS IN SAUDI ARABIA
WA'AD AL-SHAMAL Phosphoric Acid Plant (Turaif, Saudi Araiba). (March 2016 to August 2017).
Position : Electrical Protection & Commissioning Engineer.
Client : MA'ADEN, ( HANWHA & HQC) Through ABB MV Services.
Inlet Gas Treatment Project NGL (Shaybah, Saudi Arabia). (April 2013 to March 2016).
Position : Electrical Protection & Commissioning Engineer.
Client : Saudi Aramco & Samsung Engineering, Through Alfanar Factor..
115/13.8 KV GIS Al-Fakhriyah Substation (Dammam, Saudi Arabia). (Nov 2012 to March 2013).
Position: Testing & Commissioning engineer.
Client: Saudi Electric, Through ABB MV Services.
novembre 2011
A novembre 2012
Technical Support Engineer
à Alkhorayef Group
Lieu :
Arabie Saoudite - Riyad
• Provide technical assistants during and after the assembling & installation of power generator set as per the Quality control procedure (QCP), approved drawings, specifications and local authorities’ regulations. Act as a focal point to the Client.
• Visual inspection of Alternator (Stamford) & Engine (John Deere, Volvo Penta).
• Generator main winding resistance & excitation winding resistance test, Main statar insulation test, testing of AVR & Rectifier circuit (Diods & Varistor).
• Testing of Generator No load test & Full load test.
• Visual inspection of Alternator (Stamford) & Engine (John Deere, Volvo Penta).
• Generator main winding resistance & excitation winding resistance test, Main statar insulation test, testing of AVR & Rectifier circuit (Diods & Varistor).
• Testing of Generator No load test & Full load test.
octobre 2009
A octobre 2011
Solar Design Engineer
à Eastern Engineering Consultant
Lieu :
Pakistan - Peshawar
• Develop design and estimation with specifications and functional requirements for residential, commercial, or industrial solar energy systems or components.
• Determine design criteria or specifications for solar water pumping, solar street lights and solar electricity systems.
• Create drawings of engineering designs or methods for solar projects.
• Test or evaluate photovoltaic (PV) solar cells or solar modules.
• Design or develop vacuum tube collector systems
• Determine design criteria or specifications for solar water pumping, solar street lights and solar electricity systems.
• Create drawings of engineering designs or methods for solar projects.
• Test or evaluate photovoltaic (PV) solar cells or solar modules.
• Design or develop vacuum tube collector systems
Partager sur Facebook
Partager sur Twitter
Partager via Email