Electrical Supervisor at KSB PUMPS Company Ltd.
  • Pakistan - Multan
  • My current job since January 2016

 Operation and Maintenance of Reverse Osmosis and UF plants.
 Managed the diverse operation of the Reverse Osmosis and Ultra Filtration plants Operation and maintenance department which included planning, scheduling, and supervising the activities for electricians, technicians and Operators.
 Provided technical support to resolve plant breakdown issues.
 Provided technical support for all plants process control systems including Automation, Distributive Control System, Schneider Electric PLC's, motor Hybrid drives and flow controls.
 Setting and troubleshooting of VFD to start and control 3-phase induction Motors.
 Hands on Experience of control and monitoring devices like HMI Screen and PLC.
 Setting of Multiport Valves for automatic Backwashing and wash of Pre Filtration system.
 Maintenance and troubleshooting of 12V, 24V and 500V hybrid Inverters.
 Maintenance and Testing of Transformers.
 Scheduled and planned maintenance to ensure continuous operations and eliminate downtime.
 Reviewed and evaluated operations performance as compared to project plans.
 Water sampling (Feed, Product and Micro) after every 3 Months.
 CIP of RO Membranes.
 Silt Density Index test.

Apprenticeship Trainee at Kot Addu Power Company 1600MW Combine cycle power plant
  • Pakistan - Multan
  • May 2013 to May 2015

 Corrective/Preventive Maintenance, Major Overhauling (Rotor rack out/in) and testing of 100MVA, 170MVA Generators, Transformers (SIEMENS V94.2 & GE9001E) and its auxiliaries.
 Testing of all protections of generator during major overhauling.
 Inspection/maintenance and testing of 660V, 11KV and 220KV SF6 and vacuum spring
Charged air and hydraulic operated Circuit Breakers.
 Installation, repairing, Maintenance and setting of motor operated actuator Valves.
 Installation, maintenance and testing LV&MV Single phase and 3-phase Induction motors and it’s starting and control circuits.
 Electrical Maintenance of Decanting station, Fuel oil storage system, Fuel (Low sulfur furnace) oil treatment plants, thermal oil heaters, Auxiliary steam boilers and Forwarding skids.
 Operation and Maintenance Experience of Reverse osmosis and fuel (LSFO) treatment plants (centrifugal type) having capacity of 80M3/h.

Electrical Fitter at Master Engineering Works
  • Pakistan - Multan
  • September 2011 to April 2013

 Major overhauling of 170MVA Generators and Transformers.
 Testing of Generators, Transformers, Motors and their Protections with Test Inspector

Education

Bachelor's degree, ARTS
  • at Allama Iqbal Open University
  • August 2015

Maj subjects- Computer, Sociology and Food Microbiology.

Diploma, Electrical Power, Electronic & Telecomunication
  • at Government College of Technology Multan
  • September 2011

Electrical Power- About Generators, Transformers, Motors, Switch Yard Electronics- About Electrical Control Circuits Telecommunication- About diode Philip flaps, Frequency Modulation

High school or equivalent, Science
  • at Government High school daira din panah
  • November 2007

Physics, Chemistry, Electrical.

Specialties & Skills

Electrical Design
Electrical Installation
Electrical Maintenance
Electrical Testing
Electrical Controls
Provide technical support as the team installs, maintains, and repairs the Electrical Devices.
Provided technical support for plants process control systems including Automation and Distribution.
Scheduled and planned maintenance to ensure continuous operations and eliminate downtime.
Provided technical support to Technicians and Electricians to resolve plant breakdown issues.
Corrective/Preventive Maintenance, Major Overhauling and testing of 100MVA&170MVA Generators.
Operation and Maintenance of Reverse osmosis and fuel treatment plants capacity of 80 cubic meter/H.