Sr. Instrumentation Engineer
Kazmunai India Pvt. Ltd
Total years of experience :12 years, 9 Months
1. Played a key role in planning and executing of I & C site activities.
2. Coordinate weekly progress review meetings with clients/Sub-Contractors.
3. Executing job as per ITP (Inspection Test Plan)
4. Handled the responsibilities of Calibration of all Instruments and preparation of report and protocol (HART and FF type).
5. Handled job activities like Tray erection, JB Frame Erection Panel erection as per Refinery standards and preparation of Protocols.
6. Preparation of Monthly Planning report and co-ordinate with client.
7. Handled Cable Meggering, laying and Terminations and preparation of its appropriate protocols.
8. Preparation of all Quality Documents related to job activities and submission to QMD.
9. Attended Quality Audit and Safety audit monthly.
10. Well known to tackle all the job constraints.
Played a key role in planning and executing of I&C site activities
Coordinate weekly progress review meetings with clients/Sub-Contractors.
Handled the responsibilities of Calibration of all Instruments including, Control valves (HART and FF type).
Have done local commissioning and remote commissioning activities.
Well known to Configuring FF type Instruments like allotting node address, AI & DI Function block assignments and have good knowledge in error codes identification and rectification in FF Instruments of all make including Rosemount, Yokogawa, Honeywell and Endress Hauser.
Have done commissioning for RADAR instruments (Stilling well, Probe, Cone) Make: Endress Hauser, Rosemount.
Have done commissioning for Mass flow meter, Vortex Mass flow meter, Make: Endress Hauser, Yokogawa.
Well known to configure and troubleshooting of HART & FF Control valves like Fisher, Metso and Masoneilan.
Best in SIMENS control valves.
Have done commissioning for critical valves such as IGV for FD Fans, PRDS and feed water control station valves.
Have done commissioning for IR & UV flame detectors, Hydrocarbon, H2S gas detectors, SOX & NOX & O2 detectors in Stack Analyzers.
Have done document activities for Calibration certificates & commissioning related Protocols.
Handled Commission activities for Gas Turbine (FRAME-V, FRAME-VI), Heat Recovery Steam Generator, Feed water Pumps, PRDS, Utility Boilers
Under Gone Cold & Hot Loop checking.
Have done correction in Design Field instruments whether the instrument is for ESD PLC signals or for DCS controlling, if any changes occurs, it’s appropriate Document was submitted to the Client for the same Modification.
Ongoing Commissioning Activities for Natural Gas Boost Compressor for GT (Frame-VI), Natural Gas Scrubber for Utility Boilers along with Nitrogen Compressor for Sealing.
I completed Bachelor of Engineering - Electronics and Instruments Engineering at Anand Institute of Higher Technology (Allifated to Anna University) with no History of Backlogs.