Electrical Technician
First National Operation & Maintenance - Nomac
Total years of experience :12 years, 1 Months
Projects:
• MBRS park 990 MWp DEWA-V.
• MBRS park 200 MWp DEWA-2.
• Vietnam, Vinhao-6 50 MWp.
• Oman, IBRI-2 500 MWp
• Monitored SCMS & process monitoring, prepared daily generation
reports, metering data & forecast reports.
• Maintaining the breakdown records, events & troubleshooting
records.
• Initiate warranty claim follow-up & closure.
• In charge of the operations switching as per required shutdowns &
isolated the areas to ensure safe work environment.
• Updated WI's & maintenance checklists for the IMS.
• Field maintenance work on the MVPS, EAT, SUT, PV modules, SVG,
GIS, EDG, trackers, weather-stations & firefighting pumps station.
• Worked on inverters, SCB strings, transformers & trackers NCU &
SPC troubleshooting & rectification.
• Contributed to the closure of punch list points with the EPC.
• witnessed the IR & HIPOT tests done on MV & HV cables insulation.
In addition, experienced EL & IV tracing tests for the PV modules &
IR test for the string combiner boxes, WR, TTR, & DGA for the
transformers.
• Worked with Engica, SAP production, Geonica & Digsi & Synergi life
software's.
• Passed the talent development TQP tests for levels 1, 2 & 3 that're
assigned in the LMS.
• Gained solid understanding of NOMAC's plant & corporate level
documents & electrical equipment's by attending internal trainings &
conducting O&M activities.
• Responsible for the environmental management system cross audit
process safety element.
Installation, configuration, operation & troubleshooting of tracking
system (Tracker Box, Radio Box and Area
Box).
• SIEMENS SCADA monitoring.
• ABB SCADA (Hardware, and mounting with electrical panels).
• Planning and troubleshoot errors of electrical system ensuring
minimum down time.
• Maintenance of Power Transformers, Inverters, Switchgears, and
other powerplant equipment's.
• Assure optimization of the maintenance structure.
• Planning and execution of the preventive maintenance program.
• M.V cable termination and testing.
• Installation testing and commissioning of R.M.U
• Configuration of communication signals (indications, trip and close
feedback loop) of R.M.U with SCADA system.
• Calibration of gauges for mechanical protection of the transformers.
• Thermography test of electrical connections & equipment's.
• Planning & arranging with the maintenance team in case of trips,
drills or CBM situations to prepare for minimum downtime.
• Authorized to issue PTW (Issuer, Receiver, Isolation and Stop work
authority)
• Operation of various Electrical System and Utilities
• Inspection of PV area Switchgear, power Transformers, VCB's & SF6
breakers
• Planning and execution of the CM, PM & CBM
• Carry down the shut down as per RCC requirement
• Troubleshoot electrical problems to determine their cause and to
maintain the CM/PM ratio
• Maintenance of the LV/MV/HV/ equipment's UPS, batteries,
Rectifiers, and chargers
• Maintenance of Transformers, Circuit Breakers, and Disconnector
Switches
• Coordination with Load Dispatch center for operation & KVAR, P.F,
Voltage adjustment
• Inverters PM CM & CBM as per OEM recommendation and manuals
Projects:
• 1223 MW BALLOKI Powerhouse
• 500/220/132kv Sub Station Rahim Yar Khan
• 500/220 KV Sub Station New Lahore
• 220/132 KV Sub Station Gujrat
• 132/33Kv Sub Station Bahawalpur
• 500/220/132Kv Sub Station DG Khan
Job Description:
• Performed testing of (500/220/132) KV switchyard equipment as per
standard verifications of CT'S, CVT's & interlocking circuits
• Loop testing and verification of interlocking schemes of circuit
breakers Isolators earth switches.
• Installation, testing and commissioning of Auto Transformers, Power
Transformers, Circuit Breakers, Isolators, CTs, CVTs & Surge
Arresters of 11/33KV Switchgear and 132/220/500kV substation.
• Electrical Inter-Locking Scheme verification among Circuit Breakers,
Isolators, OLTC & mechanical protections of Transformer and Earth
switches.
• Stability tests (Auto transformer, power transformer and bus bars).
• Preparing RCA reports by retrieving data stored in numerical relays,
fault recorders and event recorders after faults occur in the power
system.
• Troubleshooting of protection circuits, control circuits, monitoring
circuits and communication circuits.
• Earth resistivity and mesh integrity testing at site.
• Testing of : VCB & SF6 CB's (open, close timing & contact
resistance) & Transformers (IR, TTR, WR, C&DF, Open circuit, short
circuit, zero sequence, BDV, & Functions of (cooling fan and OLTC
L/R/A).
• Testing of Surge Arresters (DC Hi-POTT Test, Counter Test).
• Testing of DS/ES (Contact Resistance Test, Function, and alignment
assurance).
• Testing of CT's (Ratio test, Polarity, Megger test, WR, Knee point &
circuit verification).
Bachelors of Electrical technology