HVAC Consultant Engineer
Self Employed
Total years of experience :41 years, 5 Months
Providing technical Expertise to HVAC Contractors in Mumbai for Installation, Testing & commissioning of HVAC Chillers, Roof Top Units and VRF units.
Review construction drawings and As built drawings, Site Supervision of on going works and Solving Technical Problems on site.
1) Implemented Company Project Quality Plan.
2) Reviewed Contractors' Method statements and ITPs Submittals.
3) Coordinated quality inspections with all the site contractors, vendors.
4) Assisted Client/PMC in establishing quality procedures/documentation.
5) Developed and monitored snag list.
6) Approved RFIs, Controlled all non-conformance reports and undertook remedial action.
7) Attended QA/QC site weekly meetings with all stake holders.
8) Witnessed and Approved Testing and commissioning of HVAC, Firefighting, Potable Water and Drainage Systems.
9) Witness FAT Test at Vendor Location and onsite.
10) Reviewed OMIMs ( Operation & Maintenance Instruction Manuals).
11) Carried out Inspection on complete MEP Systems includes HVAC System, Fire Fighting System, Plumbing works, Pumping Stations, STPs and Lifting stations, Electrical Systems-Panel Boards Installation, cable Laying and Termination, Switch gear Inspection.
12) Have also undertaken condition monitoring and TDD assignments.
Projects completed:
1) Khalifa Port (off shore) at Taweelah- Abu Dhabi.
2) KIZAD (Khalifa Industrial Zone Abu Dhabi)
3) Cruise Terminal at Zayed Port -Abu Dhabi.
4) New York University- Abu Dhabi.
5) St. Regis Resort- Abu Dhabi .
6) ADNEC.
7) SUHAIL BAHAWAN( LLC)- LOGISTIC CENTER.OMAN.
8) LULU -HYPER MARKET- OMAN.
9) Grand Hyatt-Abu Dhabi.
HVAC & Mechanical Inspector
Project: King Abdullah University of Science and Technology (KAUST) Jeddah -Saudi Arabia.
Responsibilities: Quality, Inspection, Testing and Commissioning of HVAC - 50, 000 Tons District Cooling System, Fire Fighting Systems.Pumps, sprinklers and Fire detection system etc.Potable and Sewage water network inside the building and external works. As per International standards, codes and project specifications.
Review of Drawings, Method statements, Material submittals, Operation and Maintenance manuals etc.
• Executed Preventive maintenance & Corrective maintenance of all HVAC & Refrigeration Equipment.
• Included Centrifugal & Screw chillers, 600 Tons, Roof Top Units, AHUs, FAHUs Cold storage etc.
• Inventory of Spare Parts and timely Procurement of the same to avoid delay in Maintenance work.
• Training the Maintenance team in efficient maintenance practices, Daily Safety Tool box meeting and monitoring safe work practices and Troubleshooting technical problems.
• Drafted Work Scope for outside contractors and approved contractors work.
Managed Service center in Jeddah and Makkah cities handling after sales service of Home Appliances of Gibson, Hitachi and HAAS brands. Which Included Air conditioners, Washing Machines, Ovens, T, Vs, Video cams etc.
Organized an Efficient Team of Technicians to handle service calls, Interacted with Bulk dealers in the region regarding product quality and service issues .
Held Training Workshop for the crew on new Appliances and increased number of service vehicles, which resulted in more efficient service and helped to raise product sales by 50%.
HVAC Foreman 12/1986 to 10/1996
Saline Water Conversion Corp SWCC Yanbu-Saudi Arabia
Responsibilities: Leading a team of Technicians for corrective and preventive maintenance of
HVAC.&Refrigeration Equipment.
Systems Handled: York Chillers Reciprocating and Screw Type 250 Tons, Diakin Air-cooled Condensing units, Roof top package units, Split A/c units, Cold storages, CO2 Tank Refrigerators etc.
Responsibilities: Maintenance and Operation of all HVAC and Electrical Equipment in the palaces.
Responsibilities: Erection and Commissioning of large HVAC & Refrigeration Central plants for offices, High rise buildings and Industries.in India as well as in Saudi Arabia.
Three Years Full time Diploma in Electrical Engineering