byjul rahman, lead electrical technician

byjul rahman

lead electrical technician

GASCO

Location
United Arab Emirates - Abu Dhabi
Education
Bachelor's degree, electrical and electronics engineering
Experience
7 years, 11 Months

Share My Profile

Block User


Work Experience

Total years of experience :7 years, 11 Months

lead electrical technician at GASCO
  • United Arab Emirates - Abu Dhabi
  • March 2012 to February 2015

Work involved during plant Commissioning:
 Testing and commissioning activities of GTG packages (50MVA x 8Nos) include BRUSH -Generators & Excitation Systems, GE-Gas Turbine control systems (MARKVI) & Protection Relays, ABB - Auxiliary systems and its interconnections.
 ECS and DCS interconnection with the electrical systems include GTGs and its operating philosophies.
 Executing root cause analysis, trip analysis and fault diagnosis and recommendation of measures to solve the plant problems.
 Reliability studies for the existing schemes, logics, and interlocks and arise recommendation for the reliable modification to the vendor
 Inspection of all field and substation equipments and conform to Gasco standard.
 Preparation of root cause analysis reports, incident reports, Generator control panel operating procedures, Pre commissioning and commissioning testing procedures for GTGs, Manuals for Generator Excitation & protection Systems.
 Preparation of Habshan - 5 Protection Relay testing procedure in automatic modules and manual system with OMICRON.
 Preparation of ISO documents.
Work involved after commissioned the plant:
 Have experience in Preventive Maintenance, condition monitoring and troubleshooting of the HV, MV & LV - Motors, Transformers, switchgear Panels, Battery Banks, MOV, cathodic protection transformers, AC & DC UPS, Emergency supply distribution, feeders & Bus Bars.
 Testing of ABB protection Relay - REF 615 for feeder protection, RET 615 for transformer and motors differential protection & Restricted Earth Fault protection, REM 615 for motor protection, REF 630 for directional and non-directional feeder protection.
 Handling abnormal and emergency operations, start up and shutdown of plant units.
 Making daily reports & permits system as per safety compliances.
 Adhering to management and control of safe permit to Work (PTW) system.
 Safe and smooth operation and maintenance of various electrical equipment
 As a team leader, instructing and supervising the shutdown activities especially Switchgear Bus Bar inspection HV & LV.
 Provided technical support for system operations and maintenance.
 Regular dealing with Contract Personnel for day to day maintenance activities & subsequent manpower resource management.
 Maintained effective working relationships with field crews, contractors, vendors & outside agencies.
 Executing field operation & panel monitoring with standard operating procedure of following electrical systems:
 132KV GIS ( Local control cubicle & Protection systems and cubicles)
 HV, MV&LV Switchgear (33KV, 11 KV, 3.3kV & 415V - ABB)
 HV & LV Power Transformers (132/33kV, 33/11kV, 11/3.3kV, 11/.415kV-Hyundai, Siemens & Koncar)
 HV, MV &LV motors (11kV, 3.3kV & 415V - ABB)
 AC UPS (415V & 230 V), DC UPS (110V & 48V ) - Gutor
 Battery bank preventive maintenance and capacity test activities for Lead acid & Ni-Cd Batteries.

ELECTRICAL TESTING AND COMMISSIONING ENGINEER at Electro Mechanical Company (Agent for SIEMENS AG)
  • United Arab Emirates - Abu Dhabi
  • November 2008 to March 2012

Involved Projects:
 Interconnection of ADCO/TRANSCO Power Networks 220kV GIS Extension at BAB.
 220 kV TRANSCO SS (N-4609 & N-6600) at Industrial City of Abu Dhabi - I, U.A.E
 33/11kV ADDC SS (G4010 - 2) at Industrial City of Abu Dhabi - II, U.A.E
 Protection Relay replacement and scheme modification in GASCO Substations at HABSAN & BAB.
 Testing, commissioning and scheme modification for various TRANSCO and ADDC substations.
Work Involved:
 Installation, Testing and Commissioning of LCC, Protection Panels, Bus Bar Protection Panels, Tariff Metering Panels, Interfacing Cubicles, FMS, Battery banks, Charger, Common Alarm Panels & SCMS signals.
 Substation Control and Power Cable Schedule Preparation.
 Functional Testing and Scheme Checking of the 33kV Panels 8DA10, 11kV Panels NXPLUSC & 415V LVAC Panels SIVACON.
 Testing of the 20MVA Transformer, CT, VT, CB, Stability & Sensitivity, Siemens relays (7SJ, 7UT, 7SD) & Bay Control Unit 6MD66, VA TECH Rho 3 relay for motor protection
 Preparation of commissioning procedures, test sheets for the protective relays, Control circuit testing matrix etc.
 Preparation of Red mark drawings for final AS-BUILT.
 Co ordination with client, subcontractors and manufacturers and within the organization to clear the pending snags for under warranty substations
 Control Schemes, Inter Trips and interfacing signals of the 11 & 33kV Protection Panels, Bus Bar Protection Panels, AVR Panels & Transformer MK Panels.
 Battery Banks and Its Charger & UPS Testing and Commissioning Activities.
 Substations End to End Test & Energization activities.
 Preparation of method of statements for outage and non outage jobs and Risk assessments as per client requirement to get the permit to work (PTW).
 Preparation of technical clarifications whenever necessary.

ELECTRICAL TESTING AND COMMISSIONING ENGINEER at al babtain
  • Saudi Arabia - Riyadh
  • May 2008 to November 2008

Involved Project:
 380/132/33KV, 132kV SEC-COA SS (9012) at Riyad, KSA.
Work Involved:
 Mainly involved in transformer testing up to the range of 500MVA Auto transformer.
 Testing of Insulation Resistance, Winding Resistance, Turns Ratio, Vector Group, Magnetising Current, Short circuit (Impedance measurement), zero sequence and single phase impedance, magnetic balance, oil & winding temperature sensors, cooling fans, Oil BDV & functional test of auxiliaries.
 Preparing required documents for test including equipment base design, factory test result, schematic drawing, site test results, procedure & format, approved relay settings, operation & maintenance manuals of equipment from supplier, calibration certificates for testing equipments, protection requirements, scope of work, deviations.

graduate trainee at Tamil Nadu Electricity Board
  • India
  • April 2007 to April 2008

 Testing & commissioning, Scheme modification & trouble shooting of EHV panels in 230 /110 kV Grid substations.
 Testing of CT, VT and CB (SF6) - 220kV & 110kV outdoor yard equipments.
 Power & Auto Transformer Testing up to the range of 100MVA
 Annual Relay Testing of Distance, Differential, Directional Over Current, Bus Bar Protection Relays
(Using ZFB & TURH electro mechanical Kit)

Education

Bachelor's degree, electrical and electronics engineering
  • at anna university
  • April 2006

Specialties & Skills

Switchgear
Electrical Maintenance
Protection
Transformer
relay testing,generators,substation equipment testing,commissioning & maintenance upto 220KV.

Languages

English
Expert
Tamil
Expert
Hindi
Intermediate
Arabic
Intermediate